5.9  Changing the bulb 

LED 

The devices in the OSF-4 series are all fitted with LED bulbs. 
Due  to  the  long  service  life  of  an  LED  lighting  system,  for  these  microscopes  it  will 
not be necessary to simply change a bulb. 
Problems with the lighting unit would therefore, in most cases, be caused by defects 
in the electrical system. If this is the case, then our Technical Service will be able to 
help. 

Optical data 

Features 

Model outfit

 

Kern model 

Order 
number 

OSF 

430 

OSF 

431 

OSF 

434 

OSF 

435 

Eyepieces 

WF 5x / Ø 16.2 mm 

○○ 

○○ 

○○ 

○○ 

OZB-A4101 

WF 10x / Ø 20 mm 

●● 

●● 

●● 

●● 

OZB-A4102 

WF 15x / Ø 15 mm 

○○ 

○○ 

○○ 

○○ 

OZB-A4103 

WF 20x / Ø 10 mm 

○○ 

○○ 

○○ 

○○ 

OZB-A4104 

Stand 

mechanical, with LED lighting (0.21W 
transmitted light + 1W reflected light) 

● 

● 

mechanical, incl. Fine adjustment knob,  
with LED lighting  
(0.21W transmitted light + 1W reflected 
light) 

● 

● 

Stand inlay 

Frosted glass / Ø 74.5 mm 

● 

● 

● 

● 

OZB-A4813 

black-white / Ø 74.5 mm 

● 

● 

● 

● 

OZB-A4814 

External

 

illumination 

For information on external lighting units, please see the Kern Optics main catalogue, from 
page 68

 

and visit our website www.kern-sohn.com 

● = Standard configuration

○ = Option

Содержание OSF-4

Страница 1: ...mbH Ziegelei 1 D 72336 Balingen E mail info kern sohn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com User instructions Stereo microscope KERN OSF 4 OSF 430 OSF 431 OSF 434...

Страница 2: ......

Страница 3: ...ssembly 9 5 Operation and functionality 11 5 1 Getting started 11 5 2 Adjusting the interpupillary distance 11 5 3 Adjusting the magnification 11 5 4 Dioptre adjustment and focussing 12 5 5 Adjusting...

Страница 4: ...o the electrical parts in the base of the device must not be tampered with as in this area there is an additional risk of triggering an electric shock 1 2 Notes on the electrical system Before connect...

Страница 5: ...older must not be rotated back too far If you do this there is a risk that the microscope could tip over When the microscope is not being used you should fit the objective cap and cover the microscope...

Страница 6: ...these are highly flammable substances You must therefore keep it away from naked flames and electrical devices which can be switched on and off and only use it in well ventilated rooms However organi...

Страница 7: ...OSF 4 BA e 1510 6 2 Nomenclature Using the OSF 430 as an example...

Страница 8: ...7 OSF 4 BA e 1510 Special features of OSF 434 OSF 435 The focus dial has a coarse adjustment knob and a fine adjustment knob...

Страница 9: ...d of view mm Objective Stand Illumination OSF 430 Binocular WF 10x 20 mm 20 1x 3x mechanical 1W LED reflected light 0 21W LED transmitted light OSF 431 Binocular WF 10x 20 mm 20 2x 4x mechanical 1W LE...

Страница 10: ...epieces are already fitted in the tube You just need to remove the protective film which covers them When doing this make sure that you do not touch the optical lenses with your fingers In general you...

Страница 11: ...OSF 4 BA e 1510 10 Assembled stereo microscope...

Страница 12: ...e the gap between the two eyepieces must be re adjusted While you are looking through the eyepieces use one hand to hold the righthand or lefthand prism housing firmly By rotating outwards or inwards...

Страница 13: ...k through the righthand eyepiece without dioptre adjustment ring with the right eye and bring the object into focus by using the focus control dials 4 Now set the largest magnification 5 Once again st...

Страница 14: ...ng observed should collide Torque of the focus wheels OSF 434 OSF 435 You can adjust the torque of the focus wheels by turning the ring which is fitted along the axis of the lefthand focus wheel in a...

Страница 15: ...ed by the glasses symbol on the side They are also marked in the item description by an additional H example HSWF 10x 23 mm When fitting the eye cups make sure that the dioptre setting is not moved We...

Страница 16: ...application then it often makes sense to fit an external lighting unit to overcome this problem The lighting units which are suitable for devices of the OSF 4 series are goose neck lighting units see...

Страница 17: ...7 Features Model outfit Kern model Order number OSF 430 OSF 431 OSF 434 OSF 435 Eyepieces WF 5x 16 2 mm OZB A4101 WF 10x 20 mm OZB A4102 WF 15x 15 mm OZB A4103 WF 20x 10 mm OZB A4104 Stand mechanical...

Страница 18: ...ufficient The wrong bulb has been used The input voltage is too low Optical unit Problem Possible causes You can see two images The interpupillary distance is not set correctly The magnifications of t...

Страница 19: ...materials which you can dispose of at your local recycling centre Disposal of the storage box and device must be carried out by the operator in accordance with all national or regional laws in force...

Отзывы: