background image

DIGITAL MICROSCOPE

MIC-D

REPAIR MANUAL

  

  

  

  

  

 OLYMPUS

Содержание MIC-D

Страница 1: ...DIGITAL MICROSCOPE MIC D REPAIR MANUAL OLYMPUS...

Страница 2: ...nterlock at th e zooming No B 6 C Assembly an d Disassembly pr ocedur e 1 Conn ection diagram No C 1 2 Assembl y and Disassembly pr ocedur e No C 1 2 1 Head Par t No C 2 2 2 Base Part No C 6 D Adjustm...

Страница 3: ...hooting assembly and disassembly and adjustment Repairs are to be performed by OLYMPUS authorized service tecnicians who have experience with optical adjustments of stereomicroscopes and who have a fu...

Страница 4: ...perature 0 40 Celsius Humidity 35 80 RH 2 Requires a PC for processing and observing the image 3 Supported operating systems include is not applicable MAC OS is not applicable 4 Functionnality of muit...

Страница 5: ...djustment Combinationlightintensityadjustment Automaticwhichisinterlockedwithzoom andmanualpulse 3 Illuminationsystem 3 Transmittedlight reflectedlightorobliqueilluminationispossiblethrough swing outa...

Страница 6: ...A 3 MIC D A OUTLINE OF PRODUCT Unit mm 5 Dimensions...

Страница 7: ...s displayed Remove error PC that is fulfilled hardware requirement is using Istheerrormessageshows LackofMemory Close the other applications and expand memory Close the other applications Use PC that...

Страница 8: ...ardware requirement is using Refer to the list Quit HUB connection Use recommended PC Detach the other devices Connect to only one Connect correctly Take interval more than 5 seconds at the reconnecti...

Страница 9: ...e requirement is using Refer to the list Resume function is OFF Error message of memory limitation appears Quit HUB connection Use recommended PC OFF the resume function Once the file moves to another...

Страница 10: ...intensity board is turned ON OFF by turning ON OFF the brightness adjustment knob J4 1 5 5 V of Volume switch parts ass y is OK Pulse in J4 2 of light intensity board is output Connection cable betwe...

Страница 11: ...o Illuminator LED does not light up in troubleshooting Zoomvolumeass yhasdamage orLightintensityboard hasdamage Changethem V olume switchass yhasdamage Changeit Theilluminatorshouldbe themaximumalread...

Страница 12: ...ss adjustment knob The light intensity adjustment does not interlock in all of zoom area Refer to Illuminator LED does not light up and Brightness adjustment knob does not operate in troubleshooting W...

Страница 13: ...r LED 5 Volume parts ass y When you turned the zoom Brightness changes automatically 6 Volume switch ass y You can control brightness of lighting 1 1 4 1 4 J1 J4 1 5 1 5 1 5 1 5 J1 J3 J2 J4 2 1 2 1 2...

Страница 14: ...salient of plate 4 Assemble the lens frame ass y and ND filter ass y to the head ass y 2 1 HEAD Part 2 1 Assemble plate and LED mount to head ass y 2 Fix the plate by screws 3PUK2X7SA 1 pc and 3PUK2X1...

Страница 15: ...SA 2 pcs and AWU3X4SA 2 pcs 3 Fix the LED unit by screws 3PUK2X4SA 2 pcs and washers Shaft Cover LED unit Washers 4 1 Apply grease ST 1 on washers 2 Assemble washers in arm ass y 3 Tighten stage mount...

Страница 16: ...3 Assemble spring washers 2pcs on the shaft 4 Assemble arm ass y and head ass y in the stage mount ass y 5 Fix the head ass y by screws AWU3X4SA 2 pcs 6 Fix the arm ass y by screw AWU3X6SA 1 pc 7 App...

Страница 17: ...rease Los72515 on the lens ass y 4 Assemble lens ass y on the stage mount ass y The adjustment of arm rotation tension is necessary Refer to adjustment procedure page D 1 The adjustment of illuminatio...

Страница 18: ...5 Fix the cover by screws 3PUTB2X4SA 3PUTB2X6SA 2 pcs 6 Apply adhesive on the screws 3PUTB2X4SA 3PUTB2X6SA 2 pcs The adjustment of focusing knob rotation tension is necessary Refer to adjustment proce...

Страница 19: ...e Base Name plate Polyslider Gear 4 1 Assemble volume swicth and plate 2 Assemble volume switch ass y in the base ass y Adjust the cable to the center of base ass y 3 Fix the volume switch ass y by sc...

Страница 20: ...base ass y 3 Set up the cam ass y to highest magnification position 5 1 Apply grease Los3340 to the side of shaft ass y 2 Assemble shafts in the base ass y 3 Fix the shaft ass y by screws AB3X6SA 3 p...

Страница 21: ...frame ass y 1 and Lens frame ass y 2 to base ass y 4 Assemble Lens frame ass y 1 and Lens frame ass y 2 to base ass y What has the large width What has the large width of a frame clings to the of a fr...

Страница 22: ...Apply adhesive SE9176 on the screw AHU4X4SA 1 pc 4 Stick cover in the base ass y 8 1 Assemble zoom volume ass y in the base ass y CUKSK3X4SA 2 pcs Set up the cam ass y to lowest magnification positio...

Страница 23: ...rally 5 Assemble light intensity adjustment board to the base ass y 6 Fix the light intensity ass y by screws CUKSK3X6SA 2 pcs temporally Lens frame Light intensity board 10 The adjustment of zoom par...

Страница 24: ...screws CUKSK3X6SA 2 pcs The adjustment of output voltage is necessary Refer to adjustment procedure Page D 4 The adjustment of CMOS color is necessary Refer to adjustment procedure Page D 5 The adjust...

Страница 25: ...3 Assemble cover to the base ass y 4 Apply adhesive SE9176 on the cover Stage ass y Base ass y 14 1 Band the cables together with tie wrap 2 Assemble bottom plate ass y on the base ass y 3 Fix the bo...

Страница 26: ...he amount of each rotating force are in a standard STANDARD ARM 4 5 6N HEAD 1 2N 3 In besides a standard adjust by bolting of frame or shaft 2 Rotating force adjustment of Focusing Knob 1 Tools 1 Tens...

Страница 27: ...on 2 Products 1 personal computer PC 2 USB cable 3 M01 BSW Ver 01 04 3 Preparation 1 Install the M01 BSW to PC 2 Connect the MIC D with PC by USB cable 3 Install the driver for MIC D 4 Chose the Progr...

Страница 28: ...focality highest magnification position highest magnification position When parfocality is no good When parfocality is no good 6 Remove the rubber feet and bottm plate ACU3X4SA 2pcs 6 Remove the rubbe...

Страница 29: ...ACU3X4SA 2pcs scaleseal ACU3X4SA 2pcs 11 Set up the cross specimen on stage 12 Conect the USB cable with PC 13 Setupthezoomtohighestmagnificationposition 14 Focus the specimen by knob 15 Setupthezoom...

Страница 30: ...D of MIC D is light up 3 Turn the volume switch clockwise until the maximum USB cable Clockwise 4 Connect red probe to the check pin 1 in the light intensity adjustment board Connect black probe to th...

Страница 31: ...C 2 Connect the MIC D with PC by USB cable 2 Connect the MIC D with PC by USB cable 3 Install the driver for MIC D 3 Install the driver for MIC D 4 Chose the Program Files OlympusMicro MIC D EXE folde...

Страница 32: ...D Voltage is MAX Zoom is MAX 255 Frosted filter is IN Specimen is none 4 Push the Update RGB Display button 5 Each color values are displayed Check that Green values are the 205 neighborhoods The case...

Страница 33: ...ed change the Green Limit value 7 Get the color adjustment values from Adjustment Values HEX The Color adjustment values of this MIC D are Blue 60 and Red 34 We stick the values on MIC D After adjustm...

Страница 34: ...MIC D D ADJUSTMENT PROCEDURE D 9 8 Start the MIC D EXE and input the 6034 color adjustment values in WBNo When we started the MIC D EXE we need to input the WBNo 9 Finish the color adjustment...

Страница 35: ...2 USB cable 3 M01 BSW Ver 01 04 3 Preparation 1 Install the M01 BSW to PC 2 Connect the MIC D with PC by USB cable 3 Install the driver for MIC D 4 Chose the Program Files OlympusMicro MIC D EXE fold...

Страница 36: ...ck that Cross Hairs Connectric Circles and Field Display have check 4 Set the zoom of MIC D to MAX 5 Set the cross specimen on stage Focus the specimen by focusing knob 6 Adjust the center position cr...

Страница 37: ...D to MIN 8 Check the center position of cross for adjustment and cross of specimen When optical shift is no good Loose the CUKSK3X6SA 4pcs Shake the CMOS ass y and adjust the optical shift in a standa...

Страница 38: ...oducts 1 personal computer PC 2 USB cable 3 M01 BSW Ver 01 04 3 Preparation 1 Install the M01 BSW to PC 2 Connect the MIC D with PC by USB cable 3 Install the driver for MIC D 4 Chose the Program File...

Страница 39: ...t button 3 Unite and stick 132 of a zoom indicator seal on the index of MIC D 9 scales 12 scales MIC D zoom indicator seal 2 Set the spacimen of cross on stage 3 Move the zoom until the memory of a sp...

Страница 40: ...ig NO MIC DKC02 1 LIST OF JIGS AND TOOLS 1 LIST OF JIGS AND TOOLS 1 LIST OF JIGS AND TOOLS 1 LIST OF JIGS AND TOOLS 1 LIST OF JIGS AND TOOLS 2 LIST OF PRODUCTS New Jigs Jigs Name Jigs NO Cross microme...

Страница 41: ...F 1 MIC D F LUBRICANTS AND CHEMICALS 1 LIST OF LUBRICANTS Lubricants Name OT NO Los72515 OT2008 ST 1 OT3155 Chemicals Name OT NO TB1401C OT1026 SE9176 OT1870 2 LIST OF CHEMICALS...

Страница 42: ...it up by gauze Also wipe it up by gauze with a little mixed liquid which are mixed by 70 for ether and 30 for alcohol or a little EE system washing Serial No EE 6310 that is manufactured by Olympus f...

Страница 43: ...s use both NMOS negative polanity and PMOS positive polanity circuits Since only one of the circuit types is on at any given time CMOS chips reqire less power than chips using just one type of transis...