KLN 750W 121912
3-11
3.3.14
DISPLAY BRIGHTNESS
The brightness level for the Voltage and Current displays can be set from 0 (dimmest) to 5
(brightest).
1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display
shows
(BRIT) to access BRIGHTNESS setting.
2. Press ENTER key to view setting
Brightness level (0, 1, 2, 3, 4 or 5) displayed in Current display, e.g.,
(3).
3. Rotate encoder until Current display shows desired setting, then press ENTER to confirm.
3.3.15
I/O SELECT
Used to select either RS-485 (standard) or optional GPIB or LAN interfaces for remote digital
control.
1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display
shows
(I.O) to access I/O SELECT setting.
2. Press ENTER key to view setting.
RS-485 mode displayed as
(485) in Current display.
GPIB mode displayed as
GPIB) in Current display if GPIB interface installed.
LAN mode displayed as
LAN) in Current display if LAN interface installed.
3. Rotate encoder until Current display shows desired setting, then press ENTER to confirm.
3.3.16
RS-485 BAUD RATE
Used to select baud rate for RS-485 communication. Default setting is 19.2K
1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display
shows
(485) to access RS-485 BAUD RATE setting.
2. Press ENTER key to view setting.
4800 baud rate displayed as
(4.8K) in Current display.
9600 baud rate displayed as
(9.6K) in Current display.
19200 baud rate displayed as
(19.2K) in Current display.
38400 baud rate displayed as
(38.4K) in Current display.
57600 baud rate displayed as
(57.6K) in Current display.
115200 baud rate displayed as
(115K) in Current display.
3. Rotate encoder until Current display shows desired setting, then press ENTER to confirm.
Содержание KLN 100-7.5
Страница 2: ......
Страница 4: ......
Страница 16: ...1 6 KLN 750W 121912 FIGURE 1 2 KLN 750W POWER SUPPLY OUTLINE DRAWING TWO UNITS MOUNTED IN RACK SHEET 1 OF 2...
Страница 36: ......
Страница 72: ......
Страница 86: ...Via Acquanera 29 22100 Como tel 031 526 566 r a fax 031 507 984 info calpower it www calpower it...