background image

©2015, KEPCO, INC

1

Data subject to change without notice

228-1744 REV 3

I N S T R U C T I O N   M A N U A L

BOP 1000W

 

KEPCO

KEPCO, INC. 



 131-38 SANFORD AVENUE 



  FLUSHING, NY. 11355 U.S.A.



  TEL (718) 461-7000



 FAX (718) 767-1102



http://www.kepcopower.com   



 email: [email protected]

An ISO 9001 Company.

Transition Circuit

KIT 219-0548

 

BOP 6-125MG

TRANSITION CIRCUIT KIT

1.  DESCRIPTION

Kepco KIT 219-0548 contains components used for a field upgrade of BOP 6-125MG power supplies to allow
smoother transitions through zero power when driving inductive loads at low frequencies and/or at a low rate of
output power changes. This upgrade avoids possible faults under these conditions which can cause the unit to dis-
play an error and reduce output power to zero. 

The Transition circuit detects when the voltage and the current at the BOP output have opposite signs, showing
that the unit is beginning to sink power. This turns on a preload placed between the Front End Module and the Out-
put Module of the BOP. If the Sink power increases to the point that the Source-Recuperation Detector is triggered,
the Front End switches to Sink-Recuperation mode at an increased level of power, as the preload is turned off by
the Source-Recuperation Detector. This permits a sharper transition towards Sink-Recuperation mode. If the Front
End switches to Source mode, the preload is activated for a predetermined period of time in order to boost the
power requested from the Front End, resulting in a sharper transition towards the Source mode.

2.  APPLICABILITY

This KIT applies only to BOP 6-125MG models. Contact Kepco for kits applicable to other models. This manual
applies only to Rev 2 Transition Circuit Assemblies.

3.  INSTALLATION INSTRUCTIONS

3.1  MATERIAL SUPPLIED  

(See Table 1.)

TABLE 1.  MATERIAL SUPPLIED

MATERIAL

KEPCO PART NUMBER

QUANTITY

Transition Circuit assembly (A7A3)

comprised of (1) Printed Circuit Board assembly (236-
3069), (1) Heat Sink assembly (136-0481) and other related 
components

300-0535

1

Screw, PHPH, 6-32 x 0.5 in. 

101-0519

2

Cable Assembly, A2A5 to A7A3J1 (5-Pin connector)

118-1265

1

Cable Assembly, A4A8 to A7A3J3 (4-Pin connector)

118-1266

1

Cable Assembly, A4A8 to A7A3J4 (3-Pin connector)

118-1267

1

Resistor, 150KOhms, 1%, 1/8W (R59)

115-2597

1

Resistor 200KOhms, 1%, 1/4W (R58, R70)

115-2809

2

Cable Tie

138-0076

5

Adapter Plate 

128-2412

1

Screw, FLPO, 6-32, 0.375 IN., ST 

101-0332

2

Self-adhesive Plastic Mount Cable Tie 

138-0089

3

Instruction Manual

228-1744 REV 3

1

Содержание KIT 219-0548

Страница 1: ...peration mode at an increased level of power as the preload is turned off by the Source Recuperation Detector This permits a sharper transition towards Sink Recuperation mode If the Front End switches to Source mode the preload is activated for a predetermined period of time in order to boost the power requested from the Front End resulting in a sharper transition towards the Source mode 2 APPLICA...

Страница 2: ...bled to the Heatsink with the preload MOSFET mounted directly on the heatsink Figure 1 FIGURE 1 TRANSITION CIRCUIT ASSEMBLY COMPONENT LOCATIONS 1 Attach the adapter plate provided in this kit to the Transition Circuit assembly heat sink using two flat head screws P N 101 0332 provided in this kit 2 Install the Transition Circuit assembly as shown in Figure 2 by sliding the adapter plate under the ...

Страница 3: ...lder each wire to the indicated point see Figure 3 for A4A8 component locations and Figure 6 for cable routing red wire to A4A8D1 Cathode black wire to A4A8D1 Anode white wire to A4A8TP2 3043897 CHASSIS GROUND CONNECTION SCREW QTY 2 PHPH 6 32 X 0 5 IN ST KEPCO P N 101 0519 TRANSITION CIRCUIT ASSEMBLY A7A3 A2A5 ASSEMBLY SEE FIGURE 4 A4A3 ASSEMBLY SEE FIGURE 3 A1 ASSEMBLY SEE FIGURE 2 OUTPUT MODULE ...

Страница 4: ...s as shown by Figure 6 This cable assembly has a 5 pin connector with five 5 unterminated wires Determine the needed length cut the wire and remove the insulated sleeving approximately 0 15 then sol der each wire to the indicated point of assembly A2A5 see Figure 4 for location of wire attachment points and Figure 6 for cable routing white yellow wire to A2A5D26 Anode white blue wire to junction o...

Страница 5: ... P N 115 2597 150K Ohms 1 0 125W Install and solder replacement R58 and R70 supplied P N 115 2809 200K Ohms 1 0 25W FIGURE 5 A4A3 COMPONENT LOCATIONS 8 Reinstall A4A3 by following the reverse of step 6 above 9 Perform visual inspection of transition circuit installation CAUTION After installing all components and wiring as described above perform the following checklist to verify that installation...

Страница 6: ...D AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 6 TRANSITION CIRCUIT ASSEMBLY CABLE ROUTING NOTE Components shown are typical arrangement may differ depending on unit revision ...

Страница 7: ...e voltage limit to the full scale value 6V 5 Verify that the DVM measures 10V 0 1V 6 Set the output current to negative full scale Verify the DVM measures 10V 0 1V then turn off the unit 3 4 3 A7A3R17 Measurement 1 With the unit turned off connect the DVM across A7A3R17 reference lead connected to the resistor end near est to A7A3J4 2 Disconnect the short circuit from the output and connect a resi...

Страница 8: ...nges the message flag from SOURCE to SINK and the DVM jumps from 1 24V to zero 9 Gradually decrease PS current When PS current reaches approximately 5 1A 0 8A green LED indicator A4A3DS3 goes on yellow LED A4A3DS2 goes off the BOP display changes the message flag from SINK to SOURCE and the scope will show a 15V 5mS positive pulse 10 Turn off the unit and disconnect all the test equipment from the...

Отзывы: