verify the OFF indicator above the button changes to
ON (green) indicating the output is on.

4. Program the channel by entering desired output volt-

age in the 

VOLTAGE

 field, and current limit in the

CURRENT

 field, then click 

SET

. Settings that exceed

the channel’s rated voltage/current will not be
accepted.

5. From the Operate Instrument page, click the Output

ON/OFF

 button at the upper right of the web page and

verify the OFF indicator above the button changes to
ON (green) indicating the output is on.

6. Verify the output of the BOP changes and the voltage

indication is the same on both web page and the BOP
front panel.

FIGURE 7.  BOP 2X-DE SERIES, FRONT PANEL CONTROLS AND INDICATORS

4.2.  CURRENT MODE OPERATION WITH VOLT-

AGE LIMITING. 

The BOP channel may be used as a

stabilized d-c source of positive or negative current, with
output voltage limiting (for either polarity), pre-selected for
the application at hand. Always monitor the front panel
meters while adjusting output voltage/current.

1. Refer to PAR. 3.4 and connect the load to the DC

OUTPUT Terminal Block for the channel in use.

2. Perform steps 1 through 9 of the Preliminary Checkout

(see PAR. 3.2).

3. Click on the 

MODE

 button at the upper right side of the

Operate Instrument page until the indicator above the

MODE

 button reads 

CURRENT

.

4. Program the channel by entering desired output cur-

rent in the 

CURRENT

 field and voltage limit in the

VOLTAGE

 field, then click 

SET

. Settings that exceed

the channel’s rated voltage/current will not be
accepted.

5. From the Operate Instrument page, click the Output

ON/OFF

 button at the upper right of the web page and

verify the OFF indicator above the button changes to
ON (green) indicating the output is on.

6. Verify the output of the BOP changes and the current

indication is as programmed on both the web page and
the BOP front panel.

Channel 1

A-C POWER

switch/circuit 

breaker

Channel 1

VOLTAGE MODE

indicator (green)

or

VOLTAGE LIMIT
indicator (yellow)

Channel 1 or 2

VOLTAGE 

meter (d-c Volts)

Channel 2

A-C POWER

switch/circuit 

breaker

CHANNEL 1 - 

CHANNEL 2
select switch

3044250

Channel 2

VOLTAGE MODE

indicator (green)

or

VOLTAGE LIMIT
indicator (yellow)

Channel 1

CURRENT MODE

indicator (green)

or

CURRENT LIMIT

indicator (yellow)

Channel 2

CURRENT MODE

indicator (green)

or

CURRENT LIMIT

indicator (yellow)

Channel 1 or 2

CURRENT

meter (d-c Amps)

Содержание BOP 2X-DE Series

Страница 1: ...olar limit circuits The positive and negative current or voltage limit points can be remotely programmed simultaneously or Individually Automatic crossover between each principal control loop and the...

Страница 2: ...INARY CHECKOUT A simple oper ating check after unpacking and before permanent instal lation is advisable to ascertain whether the BOP 2X DE has suffered damage in shipment 1 Install PC 15 programming...

Страница 3: ...work reduces noise ripple that may be present at the output when the output is not grounded INPUT A C CONNECTIONS Install the line cord sup plied at the rear panel and connect to 115V a c 60Hz 105V to...

Страница 4: ...to run the application A separate window opens as shown in Figure 5 Once the search is completed all found units are displayed in the Select a Unit window the MAC address appears in parentheses If you...

Страница 5: ...by default to a fixed value approximately 10 above the nominal output voltage and current of the unit Refer to the Operator s Manual see PAR 1 1 to use external reference signals in the 0 to 10V range...

Страница 6: ...nt 1 Refer to PAR 3 4 and connect the load to the DC OUTPUT Terminal Block for the channel in use 2 Perform steps 1 through 9 of the Preliminary Checkout see PAR 3 2 3 Click on the MODE button at the...

Страница 7: ...BOP Channel Voltage Limit Series and Parallel Connection of BOP Channels Remote On Off Control The following additional features are covered in the BIT 802E Operator Manual see PAR 1 1 Programming an...

Страница 8: ...8 228 1921 022720 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com...

Отзывы: