USER MANUAL
5 METHODS OF LOCATING DAMAGED PIPELINES AND UTILITIES
The methods below are based on identification of relative distortions
of signals within the damaged areas. Sometimes these distortions
are unobservable so all the readings obtained during measurement
shall be stored in the PC memory for further analysis.
5.1 Method of locating by current
This method should be used to locate broken insulation of pipelines
or utilities with considerable leakage to ground.
If a sudden drop of the current strength is revealed in the areas
without tie-in connections and branches, this will mean that a
considerable damage of the line insulation takes place. This method
is true for high initial current (of more than 0.5A) and considerable
drop of current strength after the damaged area. We recommend you
to make tracing on the frequencies of 273Hz or 526Hz.
5.2 Fault finding with insulation control
Both contact sensors of insulation control DKI-02 and A-frame, and
non-contact sensors DKI-E and DKI-P are used for location. Turn the
Tracer into the TRACE-SONDE mode. The sensors shall be
connected to the SONDE jack (Pos. 4 in Figure 1). The broken areas
are detected according to the strength of the signal from the sensors
on the SONDE scale.
At that, the utility planimetric position control shall be performed with
the «peak» and «null» methods (see Figure 4c). If the COMPASS
function is activated, locating will be performed by the position of the
utility pointer relative to the Tracer (see Figure 4d). Always control
the depth of the utility and the strength and direction of current to
avoid false trials. The current direction shall be controlled when two-
frequency signal of «1024Hz» is set on the Transmitter.
To adjust the line scale of the signal strength from the insulation
control sensors, set the pointer (Pos.3 in Figure 4) to the SONDE
position by pressing the MODE button. The gain may be selected
with the gain up/down arrows. For the automatic gain selection use
the
button.
CAUTION!
Do not supply the voltage of more than 42V to the SONDE jack
inputs.