When the Tracer moves away from the utility axis the depth readings
will increase as the distance to the utility increases. Thus, the most
significant readout is the minimum value of the utility depth.
Perform two or three measurements of the depth in one point.
The depth level shall be calculated as the average value of the
obtained results.
To check the results of measurement you may perform the following:
lift the Tracer 1.3 meters up and repeat measurements, making sure
that you hold the Tracer evenly. The readings shall increase by the
height of lifting. You may perform measurements at various
frequencies.
The «LOW FIELD» indication means that the obtained result are
certainly wrong since the received signal is too weak or the Tracer is
moved away from the target line or the utility field is distorted by the
adjacent line curr
ents. In this case, use “the 6dB method°”
(see Figure 10).
4.6.1
The indirect method of 6dB
When the Tracer fails to measure the depth of the utility line or the
depth shall be located on the passive frequencies, you may use the
indirect method of 6dB.
Figure 10
– Depth measurement by the 6dB method
Pinpoint the utility axis and store the readings of the input signal
strength on the peak scale in dB. Moving to the left and to the right of
the utility axis, find the positions in which the readings will be 6dB
less (this means that the signal strength is two times less).
The distance between these two points will be equal to double
distance from the Tracer to the utility line axis.