14
REMARKS
DISPLAY
PRESS
This section of the menu is for setting
up the variables for any options which
were ordered (Analog out or Serial
communications).
OUT LO= The rate value represented
by the 4 mA end of the 4-20 mA output
Key in the desired value and press
RST/ENTER to enter displayed value.
OUT HI= The rate value represented
by the 20 mA end of the 4-20 mA
output. Key in the desired value and
press RST/ENTER to enter displayed
value.
BAUD = Baud rate for RS 232 or RS
422 communications option. Press
any key to view existing value.
Press the PRGM key to view available
baud rates; Press RST/ENTER to en-
ter displayed value.
UNIT = Unit ID number. Key in the
desired unit number (1-99) and press
RST/ENTER to enter displayed value.
P LIST = Print list.
Press RST/ENTER to add items to list;
Press PRGM to remove items from
list.
TOTAL = Total
RATE = Rate
PEAC = Peak
UALLY = Valley
PRE A = Preset A
PRE B = Preset B
SET LO = Low Input Value
SET HI = High Input Value
END = Press RST/ENTER to exit (end) print list;
Press PRGM to recycle through list choices.
PRGM
PRGM
PRGM
PRGM
PRGM
STEP
5
SETTING
OPTIONS
OR
ENTER
PRGM
ENTER
ENTER
ENTER
ENTER
THE PROGRAM SETUP IS COMPLETE! YOU ARE NOW READY TO SET THE PRESETS.
input
RELAYS
LoC
SETuP
oPT
ouT Lo
Press any key to view
or change existing
value
ouT Hi
Press any key to view
or change existing
value
BAuD
Press any key to view
or change existing
value
9600, 1200,
2400
or
300
unit
Press any key to view
or change existing
value
P LiST
Press any key to enter
print list
ToTAL
RATE
PEAK
uALLY
PRE A
PRE B
set lo
set hi
END
Содержание INT-69R
Страница 4: ...THIS PAGE IS BLANK...