39
ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
TK-6110
14. Sensitivity
1) Sensitivity
SSG
Rear
ANT
Front
B key
SINAD 12dB or more
SENS_XXX
panel
panel
C key
Adjust the sensitivity.
All values in Low, Center and High AF VTVM
EXT.SP
TX-RX
L237
frequencies changes one time. Distortion
(A/3)
2) Select _ _L
meter
Low check
SENS_ _75 : K
Oscilloscope
SENS_ _50 : K2
4
Ω
dummy
in tune mode
load
SSG output : –116dBm/0.35
µ
V
AF output : 0.25
µ
V/4
Ω
3) Select _ _C
Center check
SENS_130 in tune mode
4) Select _ _H
High check
SENS_230 in tune mode
15. Squelch
1) Squelch tight point
Front
B key
Adjust to point of
tight point
SQ_T_XXX
panel
C key
opening squelch
Adjust the squelch tight point.
All values in Low, Center and High
frequencies changes one time.
2) Select _ _L
SQ_T_XXX in tune mode
SSG output : Value when 7dB
is added from the sensitivity
value of 12dB SINAD.
NB : ON
3) Select _ _C
SQ_T_XXX in tune mode
4) Select _ _H
SQ_T_XXX in tune mode
16. Squelch
1) Squelch open point
open point
SQ_O_XXX
Adjust the squelch open point.
All values in Low, Center and High
frequencies changes one time.
2) Select _ _L
SQ_O_XXX in tune mode
SSG output : Value when 3dB
is subtracted from the
sensitivity value of 12dB
SINAD.
NB : ON
3) SSG output : OFF
Check
Squelch must be closed.
4) Select _ _C
Front
B key
Adjust to point of
SQ_O_XXX in tune mode
panel
C key
opening squelch
5) SSG output : OFF
Check
Squelch must be closed.
6) Select _ _H
Front
B key
Adjust to point of
SQ_O_XXX in tune mode
panel
C key
opening squelch
7) SSG output : OFF
Check
Squelch must be closed.
17. NB
1) CH-SIG : 1-1
SSG
Rear
ANT
Check
SINAD 12dB or more
SSG output : –109dBm/0.8
µ
V Pulse
panel
Pulse generator
generator
Output : 0.5Vp-p/50
Ω
Cycle : 100
µ
sec
Distortion
EXT.SP
Pulse width : 10ns
meter
NB : ON
Oscilloscope
AF VTVM
SSG
Coupler
Oscilloscope
Radio
Pulse
generator
AF VTVM
Distortion
meter
4
Ω
load