ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
38
TK-6110
7. RF power
1) RF power
Power meter Rear
ANT
Front
B key
70W
70w
±
1.0W
_POW_XXX
Ammeter
panel
panel
C key
15A or less
15A or less
Adjust the RF power.
All values in Low, Center and High
frequencies changes one time.
2) Select _ _L
_POW_XXX
in tune mode
PTT : ON
3) Select _ _C
_POW_XXX
in tune mode
PTT : ON
4) Select _ _H
_POW_XXX
in tune mode
PTT : ON
8. Maximum
1) CH-SIG : 1-1
Power meter Rear
ANT
Front
B key
±
4.05kHz
±
0.1kHz
deviation
Select MXDV_XXX
Deviation
panel
panel
C key
in tune mode
meter
PTT : ON
Deviation meter filter
AF VTVM
Front
MIC
HPF : OFF, LPF : 15kHz
AG
panel
De-emphasis : OFF
Oscilloscope
AG : 1kHz/50mV
9. MIC
1) CH-SIG : 1-1
TX-RX
VR701 Check
2.2~3.8kHz
sensitivity
PTT : ON
(A/3)
Deviation meter filter
HPF : OFF
LPF : 15kHz
De-emphasis : OFF
AG : 1kHz/5mV
10. QT
1) CH-SIG : 1-4
Front
B key
±
0.75kHz
±
0.05kHz
deviation
Select QTDV_XXX
panel
C key
in tune mode
PTT : ON
Deviation meter filter
HPF : OFF
LPF : 3kHz
De-emphasis : OFF
11. DQT
1) CH-SIG : 1-6
±
0.75kHz
±
0.05kHz
deviation
Select DQDV_XXX
in tune mode
PTT : ON
Deviation meter filter
HPF : OFF, LPF : 3kHz
De-emphasis : OFF
12. DTMF
1) CH-SIG : 1-8
±
3.0kHz
±
0.1kHz
deviation
Select DTDV_XXX
in tune mode
PTT : ON
Deviation meter filter
HPF : OFF, LPF : 15kHz
De-emphasis : OFF
13. MSK
1) CH-SIG : 1-9
±
3.0kHz
±
0.1kHz
deviation
Select MSDV_XXX
in tune mode
PTT : ON
Deviation meter filter
HPF : OFF, LPF : 15kHz