33
TK-6110
ADJUSTMENT
Key Functions in Panel Test Mode and
Panel Tune Mode
Knob/Key
Test mode
Tune mode
Test mode/Tune mode changeover
Monitor ON/OFF
SCN
NB ON/OFF
Tuning value back up
MON
Frequency CH down
Tuning item down
A
Frequency CH up
Tuning item up
B
Signalling CH down
Tuning value down
C
Signalling CH up
Tuning value up
Panel Test Mode
The transceiver's transmission output, receive sensitiv-
ity, and other items are measured and QT, DQT, 2-tone and
DTMF signaling is decoded in this mode.
■
To enter the panel test mode
Hold down [MON] and turn the power switch on to enter
this mode. The test frequency channel and test signalling
channel will be displayed.
■
Function panel
Note :
When a key other than GRP down is pressed, the
optional signalling is reset.
MON
A
B
C
SCN
Volume
control
MIC
connector
Power
switch
MON key
A key
B key
C key
SCN key
LCD
TX/BUSY
LED
UP key
DW key
■
Test frequency channel (MHz) : Default setting
K
K2
CH
TX
RX
TX
RX
1 (Center)
33.300
33.400
42.500
42.600
2 (Low)
29.700
29.800
35.000
35.100
3 (High)
37.000
36.900
50.000
49.900
4
33.300
33.300
42.500
42.500
5
33.500
33.500
42.700
42.700
6
33.700
33.700
42.900
42.900
■
Test signalling channel : Default setting
CH No.
Encode tone
Decode tone
1
None
None
2
100Hz square wave
None
3
QT 67.0Hz
QT 67.0Hz
4
QT 151.4Hz
QT 151.4Hz
5
QT 210.7Hz
QT 210.7Hz
6
DQT 023N
DQT 023N
7
Single tone 1633Hz
2-tone 321.7/928.1Hz
8
DTMF [9]
DTMF [159]
9
MSK
None
Panel Tune Mode
The transceiver is adjusted in this mode.
■
To enter the panel tune mode
Press the [
] key in the panel test mode.
The adjustment items, the frequency and signalling,
other than the maximum deviation and sensitivity, return to
the values that were effective for the test frequency chan-
nel and test signalling channel before entering the panel
tune mode.
NB on
Test frequency CH
Test signalling CH