Item
Condition
Measurement
Adjustment
Specifications/Remarks
Test-
equipment
Unit
Terminal
Parts
Unit
Method
ADJUSTMENT
• Wide 5k
5) Adj item : [w SQL]
SSG
Panel
ANT
Panel
Selector After input signal
After adjusting SQL, check
Adjust : [
✳✳✳
]
knob
from SSG, press [B]
SQL open/close.
SSG output : –118dBm (0.28
µ
V) AF VTVM
Universal
key. That numeric
SSG –118dBm : Open
(MOD : 1kHz/
±
3.0kHz)
Oscilloscope
connector
will be stored in
SSG OFF : Close
memory.
[nC SQL] MOD 1kHz/
±
1.5kHz
6) Adj item : [wL SQL]
→
[sC SQL] MOD 1kHz/
±
2.4kHz
[wC SQL]
→
[wH SQL]
[wC SQL] MOD 1kHz/
±
3.0kHz
Adjust : [
✳✳✳
]
6. Low RSSI
1) Adj item : [n LRSSI]
After input signal
adjust
Adjust : [
✳✳✳
]
from SSG, press [B]
• Narrow
SSG output : –118dBm (0.28
µ
V)
key. That numeric
(MOD : 1kHz/
±
1.5kHz)
will be stored in
memory.
2) Adj item : [nL LRSSI]
→
[nC LRSSI]
→
[nH LRSSI]
Adjust : [
✳✳✳
]
• Wide 4k
3) Adj item : [s LRSSI]
Adjust : [
✳✳✳
]
SSG output : –118dBm (0.28
µ
V)
(MOD : 1kHz/
±
2.4kHz)
4) Adj item : [sL LRSSI]
→
[sC LRSSI]
→
[sH LRSSI]
Adjust : [
✳✳✳
]
• Wide 5k
5) Adj item : [w LRSSI]
Adjust : [
✳✳✳
]
SSG output : –118dBm (0.28
µ
V)
(MOD : 1kHz/
±
3.0kHz)
6) Adj item : [wL LRSSI]
→
[wC LRSSI]
→
[wH LRSSI]
Adjust : [
✳✳✳
]
7. Squelch
1) Adj item : [n SQLT]
After input signal
After adjusting SQL, check
(Tight)
Adjust : [
✳✳✳
]
from SSG, press [B]
SQL open/close.
adjust
SSG output : –113dBm (0.5
µ
V)
key. That numeric
SSG –113dBm : Open
• Narrow
(MOD : 1kHz/
±
1.5kHz)
will be stored in
SSG OFF : Close
memory.
[nC SQLT] MOD 1kHz/
±
1.5kHz
2) Adj item : [nL SQLT]
→
[sC SQLT] MOD 1kHz/
±
2.4kHz
[nC SQLT]
→
[nH SQLT]
[wC SQLT] MOD 1kHz/
±
3.0kHz
Adjust : [
✳✳✳
]
• Wide 4k
3) Adj item : [s SQLT]
Adjust : [
✳✳✳
]
SSG output : –113dBm (0.5
µ
V)
(MOD : 1kHz/
±
2.4kHz)
4) Adj item : [sL SQLT]
→
[sC SQLT]
→
[sH SQLT]
Adjust : [
✳✳✳
]
• Wide 5k
5) Adj item : [w SQLT]
Adjust : [
✳✳✳
]
SSG output : –113dBm (0.5
µ
V)
(MOD : 1kHz/
±
3.0kHz)
6) Adj item : [wL SQLT]
→
[wC SQLT]
→
[wH SQLT]
Adjust : [
✳✳✳
]