TK-3180
34
Item
Condition
Measurement
Adjustment
Specifications/Remarks
Test-
equipment
Unit
Terminal
Parts
Unit
Method
ADJUSTMENT
11. VOX1
1) Adj item : [VOX1]
AG
Panel
Universal Panel
After apply signal
adjust
Adjust : [
✳✳✳
]
connector
from AG, press [B]
AG : 1kHz/45mV at MIC terminal
key that numeric
will be stored in
12. VOX10
1) Adj item : [VOX10]
memory.
adjust
Adjust : [
✳✳✳
]
AG : 1kHz/3mV at MIC terminal
13. QT deviation 1) Remove the panel tuning
Power meter Panel
ANT
Panel
Selector 0.35kHz
±
50Hz
adjust
cable assembly from the
knob
universal connector.
Deviation
Universal
Adj item : [n QT]
meter
connector
Adjust : [
✳✳✳
]
Oscilloscope
Deviation meter filter
AG
LPF : 3kHz
AF VTVM
HPF : OFF
• Narrow
2) Adj item : [nL QT]
→
[nC QT]
→
[nH QT]
Adjust : [
✳✳✳
]
PTT : ON
• Wide 4k
3) Adj item : [s QT]
0.60kHz
±
50Hz
Adjust : [
✳✳✳
]
PTT : ON
• Wide 5k
4) Adj item : [w QT]
0.75kHz
±
50Hz
Adjust : [
✳✳✳
]
PTT : ON
14. DQT
1) Adj item : [n DQT]
0.35kHz
±
50Hz
deviation
Adjust : [
✳✳✳
]
adjust
Deviation meter filter
LPF : 3kHz
HPF : OFF
• Narrow
2) Adj item : [nL DQT]
→
[nC DQT]
→
[nH DQT]
Adjust : [
✳✳✳
]
PTT : ON
• Wide 4k
3) Adj item : [s DQT]
0.60kHz
±
50Hz
Adjust : [
✳✳✳
]
PTT : ON
• Wide 5k
4) Adj item : [w DQT]
0.75kHz
±
50Hz
Adjust : [
✳✳✳
]
PTT : ON
15. LTR
1) Adj item : [n LTR]
0.75kHz
±
0.10kHz
deviation
Adjust : [
✳✳✳
]
adjust
Deviation meter filter
LPF : 3kHz
HPF : OFF
• Narrow
2) Adj item : [nL LTR]
→
[nC LTR]
→
[nH LTR]
Adjust : [
✳✳✳
]
PTT : ON
• Wide
3) Adj item : [w LTR]
1.00kHz
±
0.10kHz
Adjust : [
✳✳✳
]
PTT : ON