TK-3180
35
Item
Condition
Measurement
Adjustment
Specifications/Remarks
Test-
equipment
Unit
Terminal
Parts
Unit
Method
ADJUSTMENT
16. DTMF
1) Adj item : [n DTMF]
Power meter Panel
ANT
Panel
Selector 1.25kHz
±
0.1kHz
deviation
Adjust : [
✳✳✳
]
knob
adjust
Deviation meter filter
Deviation
Universal
• Narrow
LPF : 15kHz
meter
connector
HPF : OFF
Oscilloscope
PTT : ON
AG
AF VTVM
• Wide 4k
2) Adj item : [s DTMF]
2.0kHz
±
0.1kHz
Adjust : [
✳✳✳
]
PTT : ON
• Wide 5k
3) Adj item : [w DTMF]
2.5kHz
±
0.1kHz
Adjust : [
✳✳✳
]
PTT : ON
17. MSK
1) Adj item : [n MSK]
1.5kHz
±
0.1kHz
deviation
Adjust : [
✳✳✳
]
adjust
Deviation meter filter
• Narrow
LPF : 15kHz
HPF : OFF
PTT : ON
• Wide 4k
2) Adj item : [s MSK]
2.4kHz
±
0.1kHz
Adjust : [
✳✳✳
]
PTT : ON
• Wide 5k
3) Adj item : [w MSK]
3.0kHz
±
0.1kHz
Adjust : [
✳✳✳
]
PTT : ON
18. TONE
1) Adj item : [n TONE]
1.5kHz
±
0.1kHz
deviation
Adjust : [
✳✳✳
]
adjust
Deviation meter filter
• Narrow
LPF : 15kHz
HPF : OFF
PTT : ON
• Wide 4k
2) Adj item : [s TONE]
2.4kHz
±
0.1kHz
Adjust : [
✳✳✳
]
PTT : ON
• Wide 5k
3) Adj item : [w TONE]
3.0kHz
±
0.1kHz
Adjust : [
✳✳✳
]
PTT : ON
19. BATT
1) Adj item : [BATT]
Power meter Panel
ANT
Panel
After pressing the
BATT terminal voltage : 5.8V
detection
Adjust : [
✳✳✳
]
PTT switch, confirm
writing
PTT : ON
DVM
BATT
that one predeter-
terminal
mined numeric in
the range 1 to 256
appears and then
press [B] key. That
numeric will be
stored in memory.