TK-290-11B
19
Item
Condition
Measurement
Adjustment
Specifications/Remarks
Test-
equipment
Unit
Terminal
Parts
Unit
Method
ADJUSTMENT
7. Maximum
1) Set panel test mode
Power meter Panel
ANT
Panel
SW A/
3.2kHz
±
0.05kHz
deviation
CH No. : 3
Deviation
SW B
(According to the
adjustment
Signaling No. : 1
meter
, –)
Select MDV
∗∗∗
Oscilloscope
in panel tuning mode
Push Monitor to 3 point
AG
Side
Universal
adjustment mode
AF VTVM
Select MDV
∗∗∗
L
AG : 1kHz/100mV
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
2) Push Tone 2 to select
MDV
∗∗∗
C
PTT : ON
3) Push Tone 2 to select
MDV
∗∗∗
H
PTT : ON
8. DQT balance 1) Set panel test mode
Make the demodu-
adjustment
CH No. : 3
lation waves into
Signaling No. : 1
square waves.
Select BLNC
∗∗∗
in panel tuning mode
Deviation meter filter setting
LPF : 3kHz
HPF : OFF
PTT : ON
9. MIC
1) Set panel test mode
Check
1.4kHz~2.9kHz
sensitivity
CH No. : 3
check
Signaling No. : 1
AG : 1kHz/10mV
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
10. QT
1) Set panel tuning mode
Panel
SW A/
0.6kHz
±
0.05kHz
deviation
CH No. : 3
SW B
adjustment
Signaling No. : 1
MIC input : OFF
Select QTDV
∗∗∗
in panel tuning mode
Deviation meter filter setting
LPF : 3kHz
HPF : 50Hz
De-emphasis : 750
µ
s
PTT : ON