TK-290-11B
18
Item
Condition
Measurement
Adjustment
Specifications/Remarks
Test-
equipment
Unit
Terminal
Parts
Unit
Method
ADJUSTMENT
3. TX high
1) Set panel test mode
Power meter Panel
ANT
Panel
SW A/
4.50W
±
0.1W
power
CH No. : 3
SW B
2.3A or less
adjustment
Signaling No. : 1
Ammeter
Select POW
∗∗∗
in tuning mode
Push Monitor to 3 point
adjustment mode
Select POW
∗∗∗
L
PTT : ON
2) Push Tone 2 to select
POW
∗∗∗
C
PTT : ON
3) Push Tone 2 to select
POW
∗∗∗
H
PTT : ON
4. TX high
1) Set panel test mode
Check
3.7W~5.2W
power
CH No. : 1
2.3A or less
check
Signaling No. : 1
PTT : ON
2) CH No. : 2
Signaling No. : 1
PTT : ON
3) CH No. : 3
Signaling No. : 1
PTT : ON
5. TX low
1) Set panel test mode
Panel
SW A/
1.0W
±
0.1W
power
CH No. : 3
SW B
1.2A or less
adjustment
Signaling No. : 1
Select POW
∗∗∗
LO
PTT : ON
6. TX low
1) Set panel test mode
Check
0.5W~1.5W
power
CH No. : 1
1.2A or less
check
Signaling No. : 1
Set low power (Push Tone 2)
PTT : ON
2) CH No. : 2
Signaling No. : 1
Set low power (Push Tone 2)
PTT : ON
3) CH No. : 3
Signaling No. : 1
Set low power (Push Tone 2)
PTT : ON