TK-290-11B
15
Panel Test Mode
This mode is used for making transceiver connection tests
and clearing the memory.
To set Panel test mode, turn on the power with [Tone 2]
and [PTT] are still held down and then first release [PTT]. This
mode cannot be set when disabled with the FPU.
In Panel test mode, when channel or signaling is selected,
the signaling that was most recently used is displayed.
Key operations in Panel test mode are as follows.
[Selector switch] : Use to select the test channel.
[PTT]
: For transmit.
[SW A]
: For down signaling.
[SW B]
: For up signalling.
[Tone 1]
: For setting Panel tuning mode.
[Tone 2]
: For switching power between Hi/Low.
Enter the LCD all lamp mode if held
down for 1 second.
[Monitor]
: For monitoring.
[Toggle]
: No function.
Frequency (MHz)
CH
RX
TX
1
155.100 (Center)
155.000 (Center)
2
136.100 (Low)
136.000 (Low)
3
173.900 (Hi)
173.975 (Hi)
4
155.000
155.000
5
155.200
155.200
6
155.400
155.400
Signaling
No.
Encode tone
Decode tone
1
None
None
2
QT 67.0Hz
QT 67.0Hz
3
QT 250.3Hz
QT 250.3Hz
4
DQT 023N
DQT 023N
5
None
None
6
DTMF (9)
DTMF (159)
7
MSK PN pattern
None
8
100Hz square wave
None
9
Tone 1 1750Hz
None
10
Tone 2 2135Hz
None
• LCD all lamp mode
Channel
Signaling
How to Remove the Flat Cable
1. Gently draw out both sides of the connector lever uni-
formly in the direction of the arrow with tweezers.
(CN101, CN400)
2. Gently rise up the connector lever in the direction of the
arrow with a fine regular screwdriver or tweezers.
(CN1, CN3, CN401, CN403)
Note:
Gently push both sides of the connector lever, when
put in the flat cable.
ADJUSTMENT
Tweezers
Flat cable
Lever
Regular screwdriver
Flat cable
Lever
• Clear function
Pressing [PTT] while holding down [Monitor] in Panel test
mode, triggers the clear function which clears all transceiver
data settings.
Panel test mode
LCD all lamp mode
[Tone 2]
holding about 1 sec.