TK-3201
22
1.Setting
1) BATT terminal votage:7.5V
2) SSG standard modulation
MOD:1kHz,DEV:1.5kHz
2.VCO lock
1) CH:5
Power meter
ANT
TC1
3.0 V
±0.1V
voltage TX
PTT:ON
DVM
CV
3.VCO lock
2) CH:1
Check
0.6V or more
voltage RX
Common Section
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Terminal
Parts
Method
Remark
1.Frequency
1) CH:5-1
Frequency counter ANT
VR1
446.05625MHz
±50Hz
Adjust
PTT:ON
2.Power
TEST CH: 5-1
Power meter
Programming
0.6W ±0.05W
Adjust
BATT terminal voltage:7.5V
Ammeter
Software:KPG-90D
0.8A or less
PTT:ON
3.VOX 1
TEST CH: 5-1
Power meter
ANT
Writing
AG:1kHz/45mV
Deviation meter
SP/MIC connector
4.VOX 10
TEST CH:5-1
Oscilloscope
Writing
AG:1KHz/3.0mV
AG
5.Max deviation TEST CH: 6-1
AF VTVM
2.2kHz
±50Hz
Adjust
AG:1kHz/150mV
(According to
Deviation meter filter
the lager +,–)
LPF:15kHz
HPF:OFF
PTT:ON
6.DQT
TEST CH: 6-1
ANT
Make the
Balance Adjust LPF:3kHz
demodulation
HPF:OFF
wave into
PTT:ON
square waves
7.QT Deviation TEST CH: 6-3
0.40kHz
±40Hz
Adjust
QT:67.0Hz
LPF:3kHz
HPF:OFF
PTT:ON
8.DQT Deviation TEST CH: 6-6
0.35kHz
±40Hz
Adjust
DQT:023
LPF:3kHz
HPF:OFF
PTT:ON
Transmitter Section
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Terminal
Parts
Method
Remark
ADJUSTMENT