![Kenwood NXR-800H Скачать руководство пользователя страница 124](http://html.mh-extra.com/html/kenwood/nxr-800h/nxr-800h_service-manual_192304124.webp)
NXR-800H
124
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
24. DQT
Deviation
1) Channel: 3 (Center)
Wide/Narrow: Analog Wide
Connect the deviation meter
to the TX ANT end via the
ATT.
Deviation meter setting
HPF: OFF
LPF: 3kHz
De-emp: OFF
Detector: Peak hold
Deviation
meter
Rear
TX ANT
PC
ADJ
±0.75kHz
±0.05kHz
Connect the deviation meter
to the TX ANT end via the
ATT.
2) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
±0.35kHz
±0.05kHz
25. CW ID
Deviation
1) Channel: 3 (Center)
Wide/Narrow: Analog Wide
Connect the deviation meter
to the TX ANT end via the
ATT.
Deviation meter setting
HPF: OFF
LPF: 15kHz
De-emp: OFF
Detector: +peak, –peak
Deviation
meter
Rear
TX ANT
PC
ADJ
±2.00kHz
±0.05kHz
Connect the deviation meter
to the TX ANT end via the
ATT.
2) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
±1.00kHz
±0.05kHz
26. Test Tone
Deviation
1) Channel: 3 (Center)
Wide/Narrow: Analog Wide
Connect the deviation meter
to the TX ANT end via the ATT.
Deviation meter setting
HPF: OFF, LPF: 15kHz
De-emp: OFF
Detector: (p-p)/2
Deviation
meter
Rear
TX ANT
PC
ADJ
±3.00kHz
±0.05kHz
Connect the deviation meter
to the TX ANT end via the
ATT.
2) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
±1.50kHz
±0.05kHz
27. DTMF
Deviation
1) Channel: 3 (Center)
Wide/Narrow: Analog Wide
Connect the deviation meter
to the TX ANT end via the ATT.
Deviation meter setting
HPF: OFF, LPF: 15kHz
De-emp: OFF
Detector: (p-p)/2
Deviation
meter
Rear
TX ANT
PC
ADJ
±2.85kHz
±0.05kHz
Connect the deviation meter
to the TX ANT end via the
ATT.
2) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
±1.50kHz
±0.05kHz
28. Courtesy
Tone
Deviation
1) Channel: 3 (Center)
Wide/Narrow: Analog Wide
Connect the deviation meter
to the TX ANT end via the ATT.
Deviation meter setting
HPF: OFF, LPF: 15kHz
De-emp: OFF
Detector: (p-p)/2
Deviation
meter
Rear
TX ANT
PC
ADJ
±1.00kHz
±0.05kHz
Connect the deviation meter
to the TX ANT end via the
ATT.
2) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
±0.50kHz
±0.05kHz
Содержание NXR-800H
Страница 180: ...1 E CN300 RX_IF_VN 168 ...