(No.RA075<Rev.001>)1-39
NXDN Mode signaling
RAN: Radio Access Number
PN9: Pseudo-Random Pattern
No.7, 9 Item: PC test mode only
4.3
Panel Tuning Mode
4.3.1 Transceiver tuning (To enter tuning mode)
To enter tuning mode, press the [ ] key while the transceiver
is in test mode. Use the [ ] key to write tuning data through
tuning modes, and the [
]/[
] key to adjust tuning
requirements (1 to 4096 appears on the LCD).
Use the [ ] key to select the adjustment item through tuning
modes. Use the [
] key to adjust 5, 6, 7 or 13 reference level
adjustments, and use the [
] key to switch between Wide/
Narrow/NXDN narrow.
LCD display in panel tuning mode
4.3.2 Key operation
4.3.3 5, 6, 7 or 13 reference level adjustments frequency
5 reference level adjustment
Sensitivity 1, Sensitivity 2, Sensitivity 3, Sensitivity 4, RSSI
Reference, Open Squelch, Low RSSI, High RSSI, Tight
Squelch
6 reference level adjustment
High Maximum Power, Medium Maximum Power, Low
Maximum Power, High Transmit Power, Medium Transmit
Power, Low Transmit Power
7 reference level adjustment
Balance, Maximum Deviation, NXDN High Deviation, QT
Deviation, DQT Deviation, DTMF Deviation, Single Tone
Deviation, MSK Deviation
No.
RX
TX
1
RAN1
RAN1
2
None
PN9
3
RAN1
Maximum Deviation
Pattern
7
FSW + PN9
FSW + PN9
9
Tone Pattern (1031Hz) Tone Pattern (1031Hz)
Key
Function
Push
Hold (1 second)
[+]
Volume up
Continuation up
[-]
Volume down
Continuation down
[
]
Adjustment value up
Continuation up
[
]
Adjustment value down
Continuation down
[
]
Auto adjustment start
-
[
]
Wide/Narrow/NXDN
Overlap point switching
[ ]
Shift to panel test mode
-
[
]
To enter 5, 6, 7 or 13
reference level
adjustments
-
[ ]
Writes the adjustment
value
-
[ ]
Go to next adjustment
item (At the time of 5, 6, 7
or 13 point adjustment:
Adjustment point change)
Back to last adjustment
item
An RAST 256
2.6
CV voltage, AD value, etc
Sub LCD
display
Low1
Adjustment point
Main LCD
display
Adjustment value
(1~4096)
Proper value guide
(When the frequency
adjustment is necessary,
or is displayed.)
Adjustment item
An: Analog narrow mode
Aw: Analog wide mode
Nn: NXDN narrow mode
Low1
Low2
Low3
Low4
Center1
Center2
Center3
Center4
Center5
High1
High2
High3
High4
[AUX
(Orange)]
Output tone pattern
change of balance
adjustment (A change is
possible only during
balance adjustment.)
-
[PTT]
(MIC)
Transmit
[0] to [9]
and
[#],[ ]
(MIC)
-
Tuning point
Display
RX (MHz)
TX (MHz)
1
Low 1
39.050000
39.100000
2
Low 4
41.050000
41.100000
3
Center 3
44.050000
44.100000
4
High 1
47.050000
47.100000
5
High 4
49.950000
49.900000
Tuning point
Display
RX (MHz)
TX (MHz)
1
Low 1
39.050000
39.100000
2
Low 4
41.050000
41.100000
3
Center 2
43.050000
43.100000
4
Center 4
45.050000
45.100000
5
High 1
47.050000
47.100000
6
High 4
49.950000
49.900000
Tuning point
Display
RX (MHz)
TX (MHz)
1
Low 1
39.050000
39.100000
2
Low 3
40.050000
40.100000
3
Center 1
42.050000
42.100000
4
Center 3
44.050000
44.100000
5
Center 5
46.050000
46.100000
6
High 2
48.050000
48.100000
7
High 4
49.950000
49.900000
Key
Function
Push
Hold (1 second)
Содержание NX-5600HB
Страница 101: ...MEMO ...
Страница 102: ... No RA075 Rev 001 JKS Printed in Japan JVCKENWOOD Corporation Communications Systems Division ...