KDC-W808/X689
15
[FM] Key ROM correction version display
When E2PROM is not installed : ROM_ERR_
When un-written : ROM_R - - -
When data is incompatible : ROM_R
∗∗∗
(Display) SYS ROM R
∗∗∗
(Display) PAN ROM R
∗∗∗
[
] Key AUDIO data default value setting
(Display) AUDIO INIT
[
] Key Short-press : CD mechanism error log display
During CD mechanism error log display ;
by long-pressing for 2 seconds, all error log
information is cleared.
(Display) I2C_
● ●
(Display) ERROR LOG
(Display) 1-
▲▲
, 2-
▲▲
, 3-
▲▲
*In “
●●
”, “OK” or “NG” is displayed. /In “
▲▲
”, “--”,
or an error code is displayed.
(*1) “Panel Open” condition
→
“EJECT” condition
“EJECT” condition
→
Counts one in “Panel open” con-
dition.
●
Initializing AUDIO-related value setting
During STANDBY sourcing, by short-pressing [
] key, AU-
DIO setting values are returned to the default values.
●
Other
• At Power ON, “CODE_OFF”, “CODE_ON” displays will not
be made.
• When staring up in the test mode, LINE MUTE prohibition
time is set to 1 second instead of 10 seconds.
• While in the test mode, security jig should not be used to
write the security code.
• While in the test mode, serial writing jig should not be used
to write the serial number.
• While in the test mode, even when a DC error is detected,
the detection information will not be written to the E2PROM.
• While in the test mode, even after an elapse of pre-set time,
the backup memory items will not be written to the E2PROM.
• Information Clear mode for Test Mode, backup/installer
memory, and CD mechanism error log
In the DC error detection information clear mode, DEMO
mode operation will not be conducted.
Also, in the above mode, the menu of the STANDBY source
will not display DEMO ON/OFF switching items.
• While in the test mode, and at the same time, PM_DET ter-
minal is H, the following will apply to the EJECT key, regard-
less of whether a disc is in the unit or not.
Panel full OPEN/CLOSE is conducted with a short-push.
(Protection time: 3 seconds)
As far as this item is concerned, eject will be achieved by 1
second long-push on the EJECT key.
• During the Test Mode, the MASK mechanism condition will
no be realized.
●
Clearing Backup Memory and Installer Memory
Data (E2PROM data clear)
1. While pressing [EQ] and [2] keys simultaneously, reset to
restart. This will initiate the initializing processes of backup/
installer memory and CD mechanism error log information.
2. When the initialization process is completed, the following
displays will be made.
Normal completion :
Abnormal completion 1 : --- backup/installer memory, ini-
tialization NG
Abnormal completion 2 : --- CD mechanism error log in-
formation, initialization NG
Abnormal completion 3 : --- All initialization processes NG
3. While in this mode, even after an elapse of a pre-set time,
no backup memory items will be written to the E2PROM.
4. This mode is released by resetting. (What was on the last
screen will not be retained.)
●
Clearing DC error detection information
(E2PROM data clear)
1. While simultaneously pressing down on [3] and [6] keys,
reset the unit to enter the DC error display mode.
2. During STANDBY sourcing, the current DC error conditions
will be displayed.
When error detected : “DC_ERR”
When error not detected : “DC_OK”
3. While the error conditions are being displayed, short-press
[AUTO]/[TI] keys to clear the detection information.
C D _ E 2 P _ _ _ :
K
A U D I O _ E 2 P :
K
C D _ E 2 P _ _ _ :
K
A U D I O _ E 2 P :
✕
C D _ E 2 P _ _ _ :
✕
A U D I O _ E 2 P :
K
C D _ E 2 P _ _ _ :
✕
A U D I O _ E 2 P :
✕
TEST MODE