lowing three levels : R15
↔
0
↔
F15. (The default value : 0)
• Using the VOL knob, the Balance is to be adjusted to the
following three levels : L15
↔
0
↔
R15. (The default value :
0)
• Using the VOL knob, Bass/Middle/Treble Level is to be ad-
justed to the following three levels : -8
↔
0
↔
+8. (The de-
fault value : 0)
• Using the VOL knob, the Sub Woofer Level is to be adjusted
to the following three levels : -15
↔
0
↔
+15. (The default
value : 0)
• Using the VOL knob, the Volume Offset is to be adjusted to
the following two levels : -8
↔
0. (The default value : 0)
• Using the VOL knob, the HPF Front/Rear is to be adjusted
to the following two levels : Through
↔
180Hz (or 220Hz ).
(The default value : Through)
• Using the VOL knob, the LPF Sub Woofer is to be adjusted
to the following two levels : 60Hz (or 50Hz)
↔
Through. (The
default value : Through)
• Using the VOL knob, the Sub Woofer Phase is to be ad-
justed to the following two levels : Reverse
↔
Normal. (The
default value : Normal)
• Volume Offset is the VOL knob and it is adjusted to the fol-
lowing 2 levels : -8
↔
0. (The default value is 0)
• Using the VOL knob, the Loudness ON/OFF is to be ad-
justed to the following two levels : OFF
↔
ON. (The default
value : OFF)
• Using the VOL knob, the 2 Zone ON/OFF is to be adjusted
to the following two levels : OFF
↔
ON. (The default value :
OFF)
• Items of Bass f/Bass Q/Bass EXT/Middle f/Middle Q/Treble
f are not included in the audio adjustment.
●
MENU Items
• By short-pressing [EQ] key, MENU can be entered.
• The [DNPP/SBF] and [DIRECT] keys on the remote con-
troller can also be used to enter the MENU.
• With the remote controller, continuous forwarding is prohib-
ited.
• When a CD is used as a source, the default item will be the
F/W Version.(DXM-6800 mechanism installed models.)
●
2-ZONE Items
• When using sources other than the STANDBY source, us-
ing a short-press on [AUTO]/[TI] key, 2-ZONE ON/OFF is
achieved.
●
Backup Current Measurement
When reset in Acc OFF (Back Up ON) condition, MUTE termi-
nal goes off after 2 seconds, instead of 15 seconds. (During
this time, the CD mechanism does not function. The MASK
mechanism will not function from the OPEN condition.)
●
OPEL Communication Items
During the test mode, OPEL communication line outputs the
following (At every 500msec, the output condition of the com-
munication line will be switched.)
●
Special display when all lights are on
When all lights are on with the STANDBY source, the follow-
ing displays are made when the keys shown below are pressed.
[1] Key
Version display
(Display) C-0405WK
(Display) SYSCOM Ver
∗
.
∗∗
(Display) PANCOM Ver
∗
.
∗∗
[2] Key
Serial number display (8 digits)
(Display) SNo xxxxxxxx
[3] Key
Short-press : Power ON hours is displayed.
During Power On hours display, by long-pressing
for 2 seconds, the Power ON hours is cleared.
(Display) PonTim xxxxx
MAX 65535 (hours)
[4] Key
Short-press : CD operation hours is displayed.
During CD operation hours display, by long-pressing
for 2 seconds, CD operation hours is cleared.
(Display) CDTim 0 xxxxx MAX 65535(hours)
[5] Key
Short-press : CD EJECT number of times is
displayed.
During CD EJECT number of times display, by
long-pressing for 2 seconds, CD EJECT number
of times display is cleared.
(Display) EjeCnt xxxxxx
MAX 65535 (times)
[6] Key
Short-press : PANEL Open/close number of times
is displayed. (*1)
During PANEL Open/close number of times
display, by long-pressing for 2 seconds, PANEL
Open/close number of times is cleared.
(Display) PnCnt xxxxxx
MAX 65535 (times)
CE
DATA
CLK
500msec
500msec
500msec