Kentatsu KFHC12H0EN1 Скачать руководство пользователя страница 3

2.   USER

2

2.1 Machine description

The fan-coil unit for the threatment of air in indoor 
environments,available in versions with casing,versions for 
building-in.

2.1.1  Standard conditions of use

The fan-coil unit is intended for the treatment of air(summer and 
winter climatisation)inside buildings used for domestic or similar 
purposes.The unit is not designed for installation in roomsused 
for laundry purposes.

CAUTION

DANGER!

The machines are designed for indoor installation for use in 
domestic or similar environments.

DANGER!

Do not introduce objects through the air intate or delivery 
grilles.

IMPORTANT!

The unit will function correctly only if the instructions for use 
are scrupulously followed,if the specified clearances are 
complied with during installation and if the operating 
restrictions indicated in this manual are strictly adhered to.

IMPORTANT!

If clearance distances are not maintained at installation,it 
could cause maintenance difficulties and reduction in 
performance.

I&O manual

2.1.2  Construction features

1. Connections for standard coil;
2. Fixing slots;
3. Defrosting tray;
4. Condensate discharge;
5. Air filter;
6. Blower;
7. Coils

;

Fig.2-1

DISPOSAL

Do not dispose this product as unsor-

ted municipal waste. Collection of such waste sepa-
rately for

 

special treatment is necessary.

Ground the air conditioner.

Do not connect the ground wire to gas or water pipes, 
lightning rod or a telephone ground wire.Incomplete 
grounding may result in electric shocks.

Be sure to install an earth leakage breaker.

Failure to install an earth leakage breaker may result in 
electric shocks.

Connect the outdoor unit wires , then connect the indoor 
unit wires.

 

You are not allow to connect the air conditioner with the 
power source until wiring and piping the air conditioner is 
done.

While following the instructions in this installation 
manual, install drain piping in order to ensure proper 
drainage and insulate piping in order to prevent 
condensation.

Improper drain piping may result in water leakage and 
property damage.

Install the indoor and outdoor units, power supply wiring 
and connecting wires at least 1 meter away from 
televisions or radios in order to prevent image 
interference or noise.

Depending on the radio waves, a distance of 1 meter may not 
be sufficient enough to eliminate the noise.

This appliance is not intended for use by persons 
(including children) with reduced physical,sensory or 
mental capabilities, or lack of experience and knowledge, 
unless they have been given supervision or instruction 
concerning use of the appliance by a person responsible 
for their safety.

Don't install the air conditioner in the following locations:

There is petrolatum existing.

There is salty air surrounding (near the coast).

There is caustic gas (the sulfide, for example) existing 
in the air (near a hot spring).

The Volt vibrates violently (in the factories).

In buses or cabinets.

In kitchen where it is full of oil gas.

There is strong electromagnetic wave existing.

There are inflammable materials or gas.

There is acid or alkaline liquid evaporating.

Other special conditions.

CAUTION

Содержание KFHC12H0EN1

Страница 1: ...uture reference I N S T A L L A T I O N O P E R A T I O N M A N U A L FAN COIL UNITS MODELS R410A KFHC12H0EN1 KFHC20H0EN1 KFHC25H0EN1 KFHC30H0EN1 KFHC38H0EN1 KFHC48H0EN1 KFHC57H0EN1 KFHC65H0EN1 KFHC78...

Страница 2: ...ll cause the set to fall water leakage electrical shock and fire The appliance must be installed 2 3m above floor The appliance shall not be installed in the laundry Before obtaining access to termina...

Страница 3: ...may result in electric shocks Be sure to install an earth leakage breaker Failure to install an earth leakage breaker may result in electric shocks Connect the outdoor unit wires then connect the indo...

Страница 4: ...mal protection and condenser permanently in circuit Structure in galvanised sheet steel Condensation collection tray with natural drainage complete with anti condensation insulation Mesh filter in reg...

Страница 5: ...sonnel or malfunctions caused by the use of non original spare parts or accessories Start stop the unit Select between the three blower speeds Thermostat adjustment and maintenance of the desired ambi...

Страница 6: ...ove the filter in version I proceed as following indicated The air filter must be cleaned by blowing it out with compressed air or washing it in water Before refitting the filter make sure it is clean...

Страница 7: ...ccordance with current health and safety regulations both as regards the equipment used and as regards the procedure followed Before commencing moving operations check that the lifting apparatus has t...

Страница 8: ...connections are made with great care by specialised fitters IMPORTANT The water coils can be partially drained through the drain valves To drain them completely they should be blown out with an air je...

Страница 9: ...fies the performance of the unit Pay attention to the safety instructions regarding ethylene glycol which are printed on the container If the unit is not used during the winter period the water contai...

Страница 10: ...ion 2 5mm2 type H05RN F The installation of room and pipe temperature sensors Outside temperature controller Fig 3 13 Inside temperature controller Fig 3 12 1 Install the room temperature sensor 1 Dis...

Страница 11: ...the electrical circuit remove any foreign bodies from the finned surface which may obstruct air flow clean off the dust with a jet of compressed air wash and brush gently with water dry with a jet of...

Страница 12: ...s important to adhere scrupulously to the following procedures The unit should only be dismantled by a firm authorized for the disposal of scrap machinery The unit as a whole is composed of materials...

Страница 13: ...1200 1000 1000 800 800 B mm 1284 1284 1284 984 984 784 784 584 584 C mm 1200 1200 1200 900 900 700 700 500 500 D mm 1226 1226 1226 926 926 726 726 526 526 626 626 115 345 203 291 115 258 74 220 143 A...

Страница 14: ...0 750 550 550 B mm 1226 12 26 1226 926 926 726 726 526 526 C mm 1200 12 00 1200 900 900 700 700 500 500 D mm 1232 12 32 1232 932 932 732 732 532 532 212 A D 545 46 105 126 345 203 291 185 258 B A C 21...

Страница 15: ...ter side pressure drops kPa 10 1 14 2 9 5 10 3 24 6 11 4 9 5 12 1 16 5 9 3 13 5 8 6 20 8 10 1 9 5 11 7 Water flow rate L H 364 492 631 774 899 1071 1343 1589 Water side pressure drops kPa 9 5 197 18 3...

Отзывы: