CONTENT

PAGE

I&O manual

PRECAUTION...........................................................................1

USER....................................................................................................2

INSTALLATION AND MAINTENANCE.......................................................6

DIMENSIONS...................................................................12

SPECIFICATION............................................................................14

Be sure to be in conformity with the local, national and 
international laws and regulations.

Read "PRECAUTIONS" carefully before installation.

The following precautions include important safty items. 
Observe them and never forget.

Keep this manual  in a handy place for future reference.

Before out from factory, FAN COIL UNIT (AIR UNITS) has 
passed Fan Coil Overpressure Resistant Test, Statically 
and Dynamically Balanced Adjustment, Noise Test, Air 
(cool) Volume Test, Electric Property Test, Outline Quality 
Detection. 

1.    PRECAUTIONS

The safety precautions listed here are divided into two categories. In 
either case, important safety information is listed which must be read 
carefully.

WARNING

After completing the installation, make sure that the unit operates 
properly during the start-up operation. Please instruct the customer 
on how to operate the unit and keep it maintained.

Be sure only trained and qualified service personnel to 
install, repair or service the equipment.

Improper installation, repair, and maintenance may result in 
electric shocks, short-circuit, leaks, fire or other damage to 
the equipment.

Failure to observe a warning may result in death.

Failure to observe a caution may result in injury or 
damage to the equipment.

CAUTION

WARNING

Install according to this installation instructions strictly. 

If installation is defective, it will cause water leakage, 
electrical shock and fire.

When installing the unit in a small room, take measures 
against to keep refrigerant concentration from exceeding 
allowable safety limits in the event of refrigerant leakage.

 

Contact the place of purchase for more information. 
Excessive refrigerant in a closed ambient can lead to oxygen 
deficiency.

Use the attached accessories parts and specified parts 
for installation. 

otherwise, it will cause the set to fall, water  leakage, 
electrical shock and fire.

The appliance must be installed 2.3m above floor.

The appliance shall not be installed in the laundry.

Before obtaining access to terminals, all supply circuits 
must be disconnected.

The appliance must be positioned so that the plug is 
accessible.

The enclosure of the appliance shall be marked by word, 
or by symbols, with the direction of the fluid flow.

For electrical work, follow the local national wiring 
standard, regulation and this installation instructions. An 
independent circuit and single outlet must be used. 

If electrical circuit capacity is not enough or defect in 
electrical work, it will cause electrical shock fire.

Use the specified cable and connect tightly and clamp 
the cable so that no external force will be acted on the 
terminal.

 

If connection or fixing is not perfect, it will cause heat-up or 
fire at the connection.

Wiring routing must be properly arranged so that control 
board cover is fixed properly. 

If control board cover is not fixed perfectly, it will cause 
heat-up at connection point of terminal, fire or electrical 
shock.

If the supply cord is damaged, it must be replaced by the 
manufacture or its service agent or a similarly qualified 
person in order to avoid a hazard.

An all-pole disconnection switch having a contact 
separation of at least 3mm in all poles should be 
connected in fixed wiring.

When carrying out piping connection, take care not to let 
air substances go into refrigeration cycle. 

Otherwise, it will cause lower capacity, abnormal high 
pressure in the refrigeration cycle.

Do not modify the length of the power supply cord or use 
of extension cord, and do not share the single outlet with 
other electrical appliances. 

Otherwise, it will cause fire or electrical shock.

If the water leaks during installation, ventilate the area 
immediately.

After completing the installation work, check that the 
water does not leak.

The cool water in the unit is not lower than 3

, hot water is 

not higher than 65

. Water in the unit must clean, air quality 

must meet to the standard of PH=6.5~7.5.

  

Содержание KFHC12H0EN1

Страница 1: ...uture reference I N S T A L L A T I O N O P E R A T I O N M A N U A L FAN COIL UNITS MODELS R410A KFHC12H0EN1 KFHC20H0EN1 KFHC25H0EN1 KFHC30H0EN1 KFHC38H0EN1 KFHC48H0EN1 KFHC57H0EN1 KFHC65H0EN1 KFHC78...

Страница 2: ...ll cause the set to fall water leakage electrical shock and fire The appliance must be installed 2 3m above floor The appliance shall not be installed in the laundry Before obtaining access to termina...

Страница 3: ...may result in electric shocks Be sure to install an earth leakage breaker Failure to install an earth leakage breaker may result in electric shocks Connect the outdoor unit wires then connect the indo...

Страница 4: ...mal protection and condenser permanently in circuit Structure in galvanised sheet steel Condensation collection tray with natural drainage complete with anti condensation insulation Mesh filter in reg...

Страница 5: ...sonnel or malfunctions caused by the use of non original spare parts or accessories Start stop the unit Select between the three blower speeds Thermostat adjustment and maintenance of the desired ambi...

Страница 6: ...ove the filter in version I proceed as following indicated The air filter must be cleaned by blowing it out with compressed air or washing it in water Before refitting the filter make sure it is clean...

Страница 7: ...ccordance with current health and safety regulations both as regards the equipment used and as regards the procedure followed Before commencing moving operations check that the lifting apparatus has t...

Страница 8: ...connections are made with great care by specialised fitters IMPORTANT The water coils can be partially drained through the drain valves To drain them completely they should be blown out with an air je...

Страница 9: ...fies the performance of the unit Pay attention to the safety instructions regarding ethylene glycol which are printed on the container If the unit is not used during the winter period the water contai...

Страница 10: ...ion 2 5mm2 type H05RN F The installation of room and pipe temperature sensors Outside temperature controller Fig 3 13 Inside temperature controller Fig 3 12 1 Install the room temperature sensor 1 Dis...

Страница 11: ...the electrical circuit remove any foreign bodies from the finned surface which may obstruct air flow clean off the dust with a jet of compressed air wash and brush gently with water dry with a jet of...

Страница 12: ...s important to adhere scrupulously to the following procedures The unit should only be dismantled by a firm authorized for the disposal of scrap machinery The unit as a whole is composed of materials...

Страница 13: ...1200 1000 1000 800 800 B mm 1284 1284 1284 984 984 784 784 584 584 C mm 1200 1200 1200 900 900 700 700 500 500 D mm 1226 1226 1226 926 926 726 726 526 526 626 626 115 345 203 291 115 258 74 220 143 A...

Страница 14: ...0 750 550 550 B mm 1226 12 26 1226 926 926 726 726 526 526 C mm 1200 12 00 1200 900 900 700 700 500 500 D mm 1232 12 32 1232 932 932 732 732 532 532 212 A D 545 46 105 126 345 203 291 185 258 B A C 21...

Страница 15: ...ter side pressure drops kPa 10 1 14 2 9 5 10 3 24 6 11 4 9 5 12 1 16 5 9 3 13 5 8 6 20 8 10 1 9 5 11 7 Water flow rate L H 364 492 631 774 899 1071 1343 1589 Water side pressure drops kPa 9 5 197 18 3...

Отзывы: