Note:
Filters and membranes are consumables. Their replacement time is dependent on the quality of raw water
and water consumption. They are not covered under the warranty. However, if a filter chokes within six months and
membrane within a year, it will be cleaned/repaired/replaced free of cost. Changing the filters and system
inspection is available on call. The treatment capacity of RO membrane will reduce with time due to clogging of
membrane pores.
“This reverse osmosis system contains a replaceable component critical to the efficiency of the systems.
Replacement of the reverse osmosis component should be with one of identical specifications as defined by
the manufacturer, to ensure the same efficiency and contaminant reduction performance.”
The reverse osmosis system contains a replaceable treatment component critical for the effective reduction of
total dissolved solids and that product water shall be tested periodically to verify that the system is performing
properly.
Replacement of spare parts are as under:-
14
-20010
SP Inline Sediment Filter 8”
-20009
SP Inline Carbon Filter 8”
-20002
SP RO Membrane Welded 8” Housing
-20015
SP Post Carbon Filter (Blue)
-20003
SP Hollow Fibre Membrane (RO)
-20018
SP FRT 550
13
MODEL NAME
KENT Superb
Model No.
Product
Applications
Purification Production Rate
Body Material
Mounting
Dimensions(mm)
Inlet Water Pressure/Temp (Min)
Inlet Water Pressure/Temp (Max)
Filter Cartridge
UV Lamp Wattage
Life of UV Lamp
Weight
Storage Capacity
Maximum Duty Cycle
Membrane Type
Booster Pump Voltage
Total Power Consumption
Input Power Supply
11037
Water Purifier With Ultra Violet Disinfection
Suitable for Purification of Brackish / Tap Water /
Municipal Corporation Water
15L/hr. or 0.25L/min*
ABS Food Grade Plastic
Wall Mounting
L 410 W 260 H 520
2
0.3 kg/ cm or 4.267psi/ 10 °C
2
3 kg/ cm or 42.67psi/ 40
°
°C
Sediment, Carbon Block Filter, UF and Post Carbon
11W
1 Year
9L
75L/day
Thin Film Composite RO
24V DC
60W
°
8.600 kg.
Single Phase 220 ± 10V AC, 50Hz
Technical Specifications
* Treatment capacity tested for tap water having TDS level of 750ppm at room temperature