SPECIFICATIONS

INBUILT & INSERT WOOD FIRE INSTALLATION

To  install  an  above  Kent  Wood  Fire  ensure  the  following  required  items  are  available;  the 

correct assembled Wood Fire and Fascia, an adequate floor protector, a zero clearance box 

if required, the correct flue components and a suitable flashing system for the roof penetration 

or chimney top to local Council requirements.

INBUILT FIRE INSTALLATION 

(TIMBER CONSTRUCTION)

The Kent inbuilt fire requires a zero clearance box when installed into a timber cavity. A floor 

protector or hearth must be used. The floor protector must extend under the wood fire and not 

less than 300mm in front of the fuel-loading and ash removal opening. The width of the floor 

protector should not be less than the width of the wood fire fascia.  

Place the wood fire into the desired position and plumb for the ceiling and roof penetrations. 

Position the wood fire to allow for the Kent triple skin flue systems 250mm outer casing to have 

a clear path through the roof. Check the proposed route of the flue to ensure it is clear of roof 

trusses and rafters in the ceiling space or other obstructions.   An inbuilt fire must be installed in 

conjunction with the Kent 

KWF298-7374

 triple skin flue kit and instructions which are included 

with the flue kit.

See page 8 for more information on zero clearance box installation.

INSERT FIRE INSTALLATION 

(MASONRY CONSTRUCTION)

Prepare  the  masonry  fireplace  to  accept  the  selected  insert  wood  fire  and  flue  ensuring 

installation requirements for width, depth and height measurements are acceptable for the 

wood  fire  to  fit  into  the  fireplace  (Refer  to  Table  1).  Determine  whether  the  flue  pipe  will  fit 

vertically in the chimney from the heater to the cowl or if an offset is required in the flue. Install 

the selected Kent wood fire into the prepared fireplace. Once in position and level, fix the fire 

to  the  base  of  the  fireplace  enclosure  with suitable  anchors.  An  insert  fire  must be  installed 

in  conjunction  with  the  Kent 

KWF298-6025 

standard  inset  flue  kit  and  instructions  which  are 

included with the flue kit.

The wood fire must be restrained against movement in the event of an earthquake. Ensure the 

Kent wood fire is restrained by fixing the wood fire to the floor protector with two bolts of 6mm 

minimum diameter through the holes provided in the outer box base. For solid concrete floors, 

use 8mm DYNABOLTS

®

 or similar, with a minimum depth of engagement into the floor of 50mm.

INSTALLING THE FASCIA

Unpack the fascia. And remove the top and bottom louvers by lifting the louver up and  then 

rotating it out from the bottom. 

Unpack  screws  and  screw  locator’s  from  supplied  bag.  Fit  screw  locator’s  to  steel  fire  box 

clipping them over precut holes in outer box.

External fire dimensions (mm)

 

Model

Model No.

Width

Depth

Height

Average 

emissions

Average  

efficiency

Rata

KWF295-6938

560

520

554

0.51g/kg

69%

Logfire II

KWF295-6937

560

520

554

0.51g/kg

69% 

TABLE 1

3

Содержание Logfire II

Страница 1: ...ing this wood fire and we suggest that the Insurance Company covering building insurance be advised of the installation 3 Kent built in wood fires when installed according to these instructions comply...

Страница 2: ......

Страница 3: ...ATION MASONRY CONSTRUCTION Prepare the masonry fireplace to accept the selected insert wood fire and flue ensuring installation requirements for width depth and height measurements are acceptable for...

Страница 4: ...ds up fix lengths together with 3 rivets or self tapping screws and slide over 150mm flue pipe from the top down to sit in position onto 200mm section of flue transition atop the Zero clearance box Ad...

Страница 5: ...m flue casing pipe from the top down to sit in position onto the 250mm section of flue transition atop the Zero clearance box Add additional 250mm sections of flue as necessary to finish at the same h...

Страница 6: ...ant bolt location Door adjustment catch pin FIG 3 Install the selected Kent wood burner into the prepared fireplace Once in position and level fix the fire to the base of the fireplace enclosure with...

Страница 7: ...flue termination is in a good clear position Your installer should be able to give advice on the best flue termination position for your situation Problems associated with wind noise or draft are almo...

Страница 8: ...of 785mm wide and 640mm deep behind the face of the wall with an additional 360mm forward of the wall face to allow for the front clearance once installed Timber framing around the Inbuilt box must h...

Страница 9: ...age initial demonstrations on how to light and operate the fire to ensure the user can confidently operate the fire for safe and efficient performance FIREWOOD Modern clean burning wood fires are desi...

Страница 10: ...rly air tight a vent may need to be installed next to the wood fire to provide the air required Lack of air will lead to a wood fire that is hard to light and get going or in bad cases to smoke spilli...

Страница 11: ...reosote deposits the interval between inspections may be increased but the flue must always be inspected and cleaned at least once a year The flue should be swept by a professional chimney sweep to re...

Страница 12: ...atches occur or the paint is damaged by over firing or aggressive cleaning agents the appliance can easily be touched up by using stove paint Any rust or other stubborn marks that may appear can be cl...

Страница 13: ...the temperature exposure Ensure ember levels do not build up to high when reloading the fire with fuel Replacing air tubes 1 Remove bricks from both sides 2 Remove the pin from the end of the old tub...

Страница 14: ...Top rear view Rata Logfire II The baffle in your Kent wood fire is an important part of the appliance and helps ensure a clean efficient and controllable burn However baffles and Promat bricks are a...

Страница 15: ...ructions supplied will render this warranty void Your Kent wood fire must be installed in accordance with the manufacturers instructions and with the appropriate approved flue system Installation must...

Страница 16: ...t date of publication and are subject to change without notice Kent products are distributed by Aber Holdings Ltd T A Aber Living 17 Mainstreet Place Te Rapa Hamilton 3200 Free Phone 0800 161 161 Free...

Отзывы: