INSTRUCTIONS FOR USE
16
Razor Blade 26D/28D – Razor Blade 28C
—
909 6457 000(1)2006-01
CHARGING THE BATTERIES
Battery charging
1.
Drive the machine on a level ground.
2.
For WET batteries only:
–
Lift the covers (1 and 13, Fig. I) and check that the
tanks (15 and 16) are empty, otherwise drain them
through the drain hose (10, Fig. C) and the tap (24).
–
Close the covers (1 and 13, Fig. I).
–
Carefully lift the tank assembly (1, Fig. J).
–
Check the level of electrolyte inside the batteries (2,
Fig. J). If necessary, adjust the level through the
caps (5, Fig. J).
–
When the correct level is reached, close the caps (5,
Fig. J) and clean, if necessary, the upper surface of
the batteries.
3.
Connect the battery charger cable plug (8, Fig. C) to the
electrical mains (voltage and frequency must be
compatible with the battery charger values on the
machine serial number plate).
If the red warning light (7, Fig. H) on the battery charger
control panel stays on, the battery charger is charging
the batteries.
4.
When the green warning light (9, Fig. H) turns on, the
battery charging is completed.
5.
Once the battery charging is completed, disconnect the
battery charger cable plug (8, Fig. C) from the electrical
mains, then roll up the cable and insert it into its housing
(7).
6.
For WET batteries only:
–
Carefully close the tank assembly (1, Fig. J).
–
Fill the tanks (15 and 16, Fig. I).
7.
Now the machine is ready to be used.
FUSE CHECK/REPLACEMENT
1.
Turn the ignition key (12, Fig. B) to “0” position.
2.
Unscrew the nuts (5, Fig. H) and carefully remove the
cover (1).
3.
Check/replace the drive system electronic board
protection fuse (60A): (3, Fig. H)
4.
Install the cover and screw the nuts.
NOTE
Charge the batteries when the yellow and the
red warning lights (7b or 7c, Fig. B) turn on, or
when finishing cleaning.
CAUTION!
Keeping the batteries charged makes them last
longer.
CAUTION!
When the batteries are discharged, charge
them as soon as possible, as that condition
makes them last shorter.
Check for battery charge at least once a week.
CAUTION!
The battery charger must be appropriate for
the batteries installed on the machine.
WARNING!
Battery charging produces highly explosive
hydrogen gas. Charge the batteries in
well-ventilated areas and away from naked
flames.
Do not smoke while charging the batteries.
While charging the battery, always keep the
tank assembly open.
WARNING!
Be extremely careful when charging the
batteries as there may be battery fluid
leakages. The battery fluid is corrosive. If it
comes in contact with the skin or eyes, rinse
thoroughly with water and consult a physician.
NOTE
When the battery charger is connected to the
mains, all machine functions are automatically
cut off.
NOTE
For further information about the battery
charger (10, Fig. H) operation, see the related
Manual.