13
4.
Drill two 1/8" (3 mm) holes that correspond to the bracket
holes of the determined mounting method. See the
following illustrations.
Floor Mounting
Rear position
Front position
Diagonal (2 options)
Wall Mounting
5.
Using the two #10 x 1
5
/
8
" (4.1 cm) Phillips-head screws
provided, mount anti-tip bracket to the wall or floor.
6.
Move range close enough to opening to allow for final
electrical connections. Remove shipping base, cardboard,
or hardboard from under range.
7.
Move range into its final location, making sure rear leveling
leg slides into anti-tip bracket.
8.
Move range forward onto shipping base, cardboard,
or hardboard to continue installing the range, using the
following installation instructions.
Position the Blower Location Template
1.
Determine and mark the centerline on the floor of the
cabinet opening.
2.
Locate the blower location template in the Installation
Parts Kit.
3.
If the countertop extends behind the opening, measure the
distance from the back edge of the cabinet cutout to the
wall.
4.
Fold the top of the blower mounting/venting template on
the line that corresponds to the countertop depth measured
in Step 3.
NOTE:
The template has lines every 1/4" (6.4 mm) from
the back edge. If the distance measured in the previous
step is 1
1
/
4
" (32 mm), fold the template on the line labeled
1
1
/
4
" (32 mm). If there is no countertop filler depth, fold the
template at zero depth
A
A. Centerline
A
A. Countertop filler depth