background image

CLEANING INSTRUCTIONS

 

The prefilter and collecting cell must be washed on a regular 
basis for the Air Cleaner to function at its peak efficiency.  
The frequency of cleaning will vary from one environment to 
another, therefore the cell should be checked monthly to 
determine cleaning schedule.  On average, the cell should be 
washed every 2-3 months. 

COLLECTING CELL

 

1.  Turn Air Cleaner 

OFF

.  Remove the cell from the Air 

Cleaner.  Slide the prefilter and carbon filter out of the 
retaining brackets before cleaning. 

2.  Rinse prefilter and cell, and spray completely with DAX 

Detergent (or non-chlorine, non-corrosive, non-abrasive, 
non-ammonia liquid household detergent).  Let stand for 
5 minutes.  Rinse well with hot water (120°F / 49°C 
maximum). Repeat process 3 times. 

3.  If dirt remains, let cell soak in a solution of DAX 

Detergent and hot water for 30 minutes. 

4.  For drying, place the cell on a 45° angle on one end, 

with the arrow pointing sideways, and let stand for 10-24 
hours.  A hair dryer may be used to speed up drying 
time.  Make sure the cell is completely dry before 
reinserting back into Air Cleaner. The arrow on the cell 
must point toward the fan blower. 

5.  If arcing or snapping occurs or the lights do not come on 

when the cell is placed back in the unit and turned on, 
then remove the cell and allow to dry longer. 

 
ODOUR & GAS (VOC) REMOVAL FILTER 

 
 

 
 
1.  The Activated Carbon Odour & Gas (VOC) Removal 

Filter must be replaced at regular intervals if odour 
removal is desired (approximately every 3-6 months). 

ODOUR REMOVAL FILTERS ARE NOT WASHABLE.

 

CABINET 

1.  Turn Air Cleaner 

OFF

2.  A soft, damp, lint-free cloth may be used to remove dirt 

and fingerprints from painted surfaces, grills and end 
panels. 

NEVER USE AN ABRASIVE CLEANER ON THE 
CABINET.

 

WARNING 

• 

DO NOT WASH COLLECTING CELL IN 
DISHWASHER

.

 

• 

Never use any object to clean between the cell plates as 
this may cause damage to the plates or ionizing wires. 

• 

Never place the cell in an oven to dry. 

• 

The edges of the cell may be sharp — handle with care. 

 
 
 
 

TROUBLESHOOTING CHART 

 
The two Operation Lights, located behind the front grill, are 
also used as the high voltage fault indicator.  If the fan is 
operating, but the lights do not come on, then there is a 
problem in the high voltage circuit.  To determine what the 
problem is, turn the Air Cleaner 

OFF

 and remove the 

collecting cell.  Close the lid and turn the Air Cleaner back 

ON

.  If the lights come back on, the problem lies in the cell.  

Check the cell for wetness from washing or look for a broken 
ionizing wire(s) or bent cell plate(s). 
 
If the lights do not come on, the problem is with the power 
board or Operation Light(s).  If you are unable to correct any 
of the above problems, call 1-800-267-8305.

 

TECHNICAL DATA

 

PROBLEM 

CAUSE 

Fan does not operate 
Both Operation Lights off 

• 

Unit not plugged in 

• 

System switch not 

ON

 

• 

Fan switch not in proper position 

• 

Lid not securely closed 

Green Performance 
Light on 
Red Ion Light off 

• 

Negative Ion switch not in 

ON 

position 

Fan operating 
Both Operation Lights off 

• 

Cell wet from washing 

• 

Short in cell (see below) 

Cell arcing excessively 

• 

Cell wet from washing 

• 

Cell plate(s) bent 

• 

Cell dirty or large lint ball/hair 
caught in cell 

• 

Broken ionizing wire(s) 

• 

Prefilter is in backward (black 

 

mesh should be visible on outside) 

Air Cleaner vibrating 
excessively 

• 

Unit not sitting on flat surface 

Both Operation Lights on 
Cell not collecting dirt 

• 

Cell is in backward (Arrow on cell 
should point towards fan blower) 

Dimensions 

Width 

Depth 

Height 

 

20.0 in 
12.0 in 
  5.0 in 

 

50.8 cm 
30.5 cm 
12.7 cm 

Weight 

  16.0 lbs 

  7.3 kg 

Input Voltage 

120 V              60 Hz 

 

Power Consumption 
(maximum) 

85 Watts 

 

Air Flow 

High 

Medium 

Low 

 

130 cfm 
  80 cfm 
  60 cfm 

 

221 m³/hr 
136 m³/hr 
102 m³/hr 

Cell Output Voltage  

6500 VDC @ < 1 mA 

 

Collecting Cell 
Surface 

756 in² 

4877 cm² 

Negative Ionizer 

-5000 VDC @ <.1 mA 

 

Negative Ion Output 

2 x 327.7 K/in³ 

2 x 20 K/cm³ 

Ideal for rooms up to:  
(1 room air change 
every 20 minutes for 
maximum room size) 

 

320 ft² 

 

29.5 m² 

Activated Carbon 
Odour & Gas (VOC) 
Filter 
 
Prefilter 

Collecting Cell 

DAX Detergent, No. 32921, 
and the Activated Carbon 
Odour & Gas (VOC) Removal 
Filter, No. 32711, are 
available from your Sears 
outlet.

 

Содержание D42 M32701

Страница 1: ...ing smoke and grease and more down to 0 01 micron Activated Carbon Odour Gas VOC Removal Filter removes Volatile Organic Compounds emitted from common sources within the home and office Dual Negative Ionizer restores the air s natural ion balance Quiet 3 Speed Fan is comfortable for room occupants Performance Indicator Light shows Air Cleaner is operating properly at a glance Ideal for rooms up to...

Страница 2: ...id which activates Safety Interlock 2 Negative Ion Emitter 3 Negative Ion Control Switch 4 3 Speed Fan Control Switch 5 System Switch 6 Operation Lights 6 The Fan Control Switch in the front position is low speed the center position is medium and the rear position is high speed 7 The negative ions are controlled by a separate switch located behind the fan control switch When the switch is ON the r...

Страница 3: ...the cell may be sharp handle with care TROUBLESHOOTING CHART The two Operation Lights located behind the front grill are also used as the high voltage fault indicator If the fan is operating but the lights do not come on then there is a problem in the high voltage circuit To determine what the problem is turn the Air Cleaner OFF and remove the collecting cell Close the lid and turn the Air Cleaner...

Страница 4: ...not use the Air Cleaner when oxygen is being used or when combustible gases are present 13 The Air Cleaner has slots or openings in the cabinet for ventilation purposes to provide reliable operation of the unit and to protect it from overheating These openings must not be blocked or covered 14 The Air Cleaner should be operated only from the type of power source indicated on the rating label If yo...

Отзывы: