background image

BENEFITS 

• 

Helps provide relief from allergy, asthma and respiratory 
illness. 

• 

Helps clear a smokey environment quickly, so everyone 
can work and relax together. 

• 

Helps reduce the time and money spent cleaning and 
redecorating.  Prevents damaging black dust from 
staining walls, upholstery and window coverings. 

• 

Helps reduce tobacco, cooking and pet odours. 

• 

Revitalizes the air with healthy negative ions. 

• 

Improves indoor air quality for a fresher, more 
comfortable environment, year-round. 

HOW IT WORKS

 

Dirty air is drawn in through the front grill and passes through 
a 4-stage filtering system. 

The Prefilter consists of aluminum mesh and a close knit 
polymesh.  It prevents larger particles, lint and hair from 
entering the collecting cell. 

The next step is a 2-Stage Electrostatic Collecting Cell.  Dirt 
particles are charged with a high positive voltage by a series 
of fine ionizing wires. The charged particles are drawn 
through to the collecting plates where the dirt adheres to the 
grounded plates, and remains until the cell is taken out and 
washed. Removes particles down to 0.01 micron 
(1/2,540,000 of an inch). 

The air is then drawn through an Activated Carbon Odour & 
Gas VOC (Volatile Organic Compound) Removal Filter to 
help remove offensive odours and gases.  Clean air is then 
discharged out the top of the Air Cleaner. 

Dual Negative Ionizer needles are located in the clean air 
stream.  Adding healthy negative ions to the air revitalizes 
the air similar to that near a waterfall, spring, the ocean, or 
after a rainfall.  Studies have shown that negative ions have 
a beneficial effect on human biochemistry, both physically 
and mentally. 

OPERATING INSTRUCTIONS 

1.  Remove the Air Cleaner from the box and check for 

apparent damage.  If your unit has any signs of damage, 
immediately contact the store where the Air Cleaner was 
purchased. 

2.  Keep the shipping carton in case the need arises to 

store or transport the unit. 

3.  Remove all packaging from the unit.  Choose a suitable 

table or stand to allow unobstructed circulation from front 
and top of unit.  The unit performs best when the back is 
against a wall.  This enhances air circulation.  To mount 
unit on wall, refer to the Wall Mount Instructions. 

4.  Operate Air Cleaner at voltage shown on back of unit. 

5.  The System Switch controls the power to the Fan 

Control Switch and the power board.  When the System 
Switch is 

ON,

 the green light behind the front grill will be 

illuminated. 

 

 

2

 3 
 4 
 5 
 6 

 
 
 
 
 
 
 

 

 
 
 

 

1 - Lid which activates Safety Interlock 

 

2 - Negative Ion Emitter 

 

3 - Negative Ion Control Switch 

 

4 - 3-Speed Fan Control Switch 

 

5 - System Switch 

 

6 - Operation Lights 

6.  The Fan Control Switch in the front position is low 

speed, the center position is medium, and the rear 
position is high speed. 

7.  The negative ions are controlled by a separate switch 

located behind the fan control switch.  When the switch 
is 

ON

, the red light will be illuminated.  

Note:  The 

Negative Ion Emitter will not work without the 
System Switch being ON.

 

8.  To access the prefilter, collecting cell or activated carbon 

filter, press firmly on the right front dimple on the lid and 
release.  Lift the lid releasing it from the magnet. 

WALL MOUNT INSTRUCTIONS 

1.  To mount Air Cleaner on wall, remove the rear feet (2) 

from the bottom of the Air Cleaner, to expose the 
keyhole slots. 

2.  To remove the feet from the Air Cleaner, you will need a 

small, flat screwdriver.  Pry up the center pin of the rear 
foot until the head protrudes above the foot.  Place the 
flat portion of the screwdriver under the foot and pry up.  
This will release the foot from the cabinet.  Keep the feet 
in case you wish to table mount the unit in future. 

3.  Find the location on the wall where you wish to place the 

Air Cleaner.  The unit should be placed 3 feet (1 m) 
below the ceiling.  Use appropriate fasteners for the type 
of wall the unit will be mounted and insure the head of 
the screw will fit into the larger opening of the keyhole 
slot.  The screw head should be larger than the smaller 
opening of the keyhole.  The Air Cleaner weighs 
approximately 20 lbs (9 kg).  The distance between the 
holes in the cabinet bottom is 16 3/4 in (42.5 cm). 

4.  After placing the screws in the wall, adjust the amount of 

the screw sticking out to approximately 1/8 in (.32 cm).  
Place the Air Cleaner over the screw head and allow the 
head to slip into the keyhole slot.  Pull the unit down 
slightly to allow the screw head to slide into the smaller 
portion of the slot.  

Use the low or medium speed for quiet, continuous or 
nighttime use. Use the high speed for initial cleaning of heavy 
concentrations of dirty air (i.e. smoke) or after leaving the 
room. 

1 Dirty Air 
 
 
 
2 Prefilter 
 
 

3 Ionizing 
   Section 

4 Collecting Cell 
   Plates 
 
5 Odour & Gas 
   Removal Filter 
 
7 Negative Ions 
   and Clean Air 

6 Ionizing Needle 

You may notice arcing or snapping from the cell.  It is normal 
to hear some arcing when the unit is new or first turned on.  
Arcing in the cell may also be caused by high humidity (over 
80%), after washing, or when a large particle of dirt or hair is 
caught in the cell.  If the arcing is continuous and constant, 
then refer to the Troubleshooting Chart. 

Содержание D42 M32701

Страница 1: ...ing smoke and grease and more down to 0 01 micron Activated Carbon Odour Gas VOC Removal Filter removes Volatile Organic Compounds emitted from common sources within the home and office Dual Negative Ionizer restores the air s natural ion balance Quiet 3 Speed Fan is comfortable for room occupants Performance Indicator Light shows Air Cleaner is operating properly at a glance Ideal for rooms up to...

Страница 2: ...id which activates Safety Interlock 2 Negative Ion Emitter 3 Negative Ion Control Switch 4 3 Speed Fan Control Switch 5 System Switch 6 Operation Lights 6 The Fan Control Switch in the front position is low speed the center position is medium and the rear position is high speed 7 The negative ions are controlled by a separate switch located behind the fan control switch When the switch is ON the r...

Страница 3: ...the cell may be sharp handle with care TROUBLESHOOTING CHART The two Operation Lights located behind the front grill are also used as the high voltage fault indicator If the fan is operating but the lights do not come on then there is a problem in the high voltage circuit To determine what the problem is turn the Air Cleaner OFF and remove the collecting cell Close the lid and turn the Air Cleaner...

Страница 4: ...not use the Air Cleaner when oxygen is being used or when combustible gases are present 13 The Air Cleaner has slots or openings in the cabinet for ventilation purposes to provide reliable operation of the unit and to protect it from overheating These openings must not be blocked or covered 14 The Air Cleaner should be operated only from the type of power source indicated on the rating label If yo...

Отзывы: