28
After Natural Gas Setting, applying Propane Gas Orifice or wrong use of Natural Gas
Orifice will result in fire. Conversion must be made by a qualified technician.
Initially
, Natural Gas mode is set. Propane Gas Orifice is on sale as a Service
Part to authorized servicers only.
!
Warning
STEP 1 : VALVE SETTING
Full open
Change screw
STEP 2 : ORIFICE CHANGE
Orifice
Gas type
Natural Gas
Propane Gas
Marking
NCU
PCK
Shape
Orifice P/No
4948EL4001B
4948EL4002C
Close
Change screw
ധ
Remove 2 screws.
ന
Disassemble the pipe assembly.
ഩ
Replace Natural Gas orifice with Propane Gas orifice.
આ
Kit contents
: Orifice (Dia. = 1.471mm, for Propane Gas)
: Replace Label
: Instruction sheet
11
CHANGE GAS SETTING (NATURAL GAS, PROPANE GAS)