11
Component
Test Procedure
Check result
Remark
7. Heater
Measure resistance of the
following terminal
①
Terminal : 1 (COM) - 2
②
Terminal : 1 (COM) - 3
③
Terminal : 2 - 3
①
Resistance value : 10
Ω
②
Resistance value : 10
Ω
③
Resistance value : 20
Ω
· Electric type
8. Thermistor
Measure resistance of terminal
to terminal
Temperature condition :
58
∞
F ~ (10~40
∞
C)
58
∞
F ~ 104F (10~40
∞
C)
Resistance value : 10
Ω
· Heater case -
Hi limit
· Electric type
9. Motor
· See Page 13
10. Gas valve
valve 1
valve 2
Measure resistance of the
following terminal
①
Valve 1 terminal
②
Valve 2 terminal
①
Resistance value : > 1.5kg ~
②
Resistance value :
> 1.5~2.5kg
· Gas type
11. Igniter
5318EL3001
MEQ61841001
Measure resistance of terminal
to terminal
Resistance value
100~800
Ω
(for 5318EL3001)
40-150
Ω
(for MEQ1841001)
· Gas type
12. Frame Detect
Measure resistance of terminal
to terminal
①
Open at 370
∞
F ((Maximum)
②
Close at 320
∞
F
①
Resistance value
≒
∞
②
Resistance value < 1
Ω
· Gas type
①
②
③
Содержание 796.8102