17
9-2. Troubleshooting for Steam Dryer
9-3. Display Fault/Error Codes for Steam Dryer
PROBLEM
Water drips from nozzle
when Steam Cycle starts.
This is normal.
This is normal.
This is normal.
This is normal.
This is steam condensation.
The dripping water will stop after a short time.
The drum does not turn
during Steam Cycle.
The drum is turned off and only tumbles
intermittently so that the steam vapor
remains in the drum.
Can not see steam vapor
at the beginning of
cycle.
The display shows:
MORE TIME
pressed.
Pressing the MORE TIME button adjusts the
load size from 1 to 5 articles or a big load
indicated by in the display.
Steam is not visible
during Steam Cycle.
This is normal.
Steam vapor is difficult to see when the
door is closed, although condensation
may form on the inside of the door.
Steam is released at different stages of the
cycle for each option. Steam will not normally
be visible, although condensation may form on
the inside of the door.
Top plate of the dryer is
very warm.
Top plate gets very warm during steam
operation.
SOLUTIONS
POSSIBLE CAUSES
The error codes below will be displayed when attempting to start a drying
cycle, or after activating the Diagnostic Test mode.
tE4
E1
E3
E4
E5
Thermistor of
steam generator
Steam generator thermistor open or shorted. tE4 error is only displayed in the test mode.
Replace the steam generator.
If water in the steam feeder is less than about 2/3 full,
this error may be displayed. Fill the feeder and restart
the cycle.
Steam generator element is not heating and generator
may need to be replaced.
E5 error is only displayed in the test mode.
Replace the steam feeder pump.
Check the hose and nozzle for clogging.
CAUTION:
The hose and nozzle will be extremely hot
during and immerdiately after steam operation.
Steam generator temperature exceeds
116 deg for more than 3 seconds.
Steam hose or nozzle is clogged.
Sensors do not detect that steam generator
is full within 60 seconds.
Steam generator temperature does not
rise 4
∞
C every 2 minutes or the
temperature is less than 80
∞
C for 3 seconds
after steam temperature has been reached.
When the AD value of the pump less than
10 in the test mode.
Steam generator
Steam generator
Steam generator
Pump
DISPLAY
CAUSE
REMARK
CHECKING PART
Содержание 796.8102
Страница 2: ...OCT 2009 PRINTED IN KOREA P No MFL92119904 ...
Страница 6: ...2 FEATURES AND BENEFITS 5 Apply Model 796 8219 796 9219 900 Apply Model 796 8102 796 9102 900 ...
Страница 15: ...7 CONROL LAY OUT PCB ASSEMBLY DISPLAY LAY OUT PCB ASSEMBLY LAY OUT 14 ...
Страница 41: ...13 EXPLODED VIEW 49 13 1 Control Panel Plate Assembly A130 A210 A211 A120 A140 A110 ...