![Kenmore 795.78733.804 Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/kenmore/795-78733-804/795-78733-804_service-manual_1955034051.webp)
- 51 -
No
Yes
First Water- valve
Is the resistance value
between (1) and (2) of the
First-water valve like as
below?
(1)
(2)
360 ~ 420 ½
(1) To (2)
Result
Test Point
Checking resistance of First-valve
No
Yes
Second Water- valve
Is the resistance value of
Second-water valve like as
below?
(1)
(2
Main PWB
CON3
Pin11 GY
Pin4 BL
)
360 ~ 420 ½
(1) To (2)
Result
Test Point
Door
Dispenser
Ice Maker
No
Yes
115 V
Pin4 To pin11
Result
Test Point
Chec
Output voltage of machine room water valve
king resistance of Second-valve
Replace
First
Water-valve
(Position No:
619A)
Replace
Second
Water-valve
(Position No:
619B)
Machine room
In door
In Water Mode,
Is the voltage between
pin4 and pin11 of CON3 in
main PWB like as below,
while pushing the level
switch?
Replace
MAIN PWB
(Position No:
500A)
No
Yes
Is the condition of
the micro switch like as
below?
Replace
Micro
Switch
(Position
No:402C)
After plug in,
explain to the customer!
Infinity
Normal
0 ½
Push the Lever
Tester
Status
(1)
(2)
Содержание 795.78733.804
Страница 24: ...5 CIRCUIT DIAGRAM 24 ...
Страница 71: ... 71 7 9 Main PWB Assembly EBR41956404 CON1 CON2 CON3 CON4 CON5 CON6 CON9 ...