- 48 -
No
Yes
No
Yes
No
Yes
(1)(2)
2.38 ~ 4.02 ½
(1) To (2)
Result
Test Point
No
Yes
(1)(2)
32 ~ 40 ½
(1) To (2)
Result
Test Point
Is the resistance value
between (1) and (2) of the
Auger motor like as below?
Is the resistance value
between (1) and (2) of the
cube solenoid like as below?
Replace
Cube Solenoid
(Position No:
614A)
Replace
Auger Motor
(Position No:
606A)
Replace
Dispenser
PWB
(Position No:
155A)
115 V
pin2 To pin10
Pushing
Normal
Lever
switch
0V
pin2 To pin10
Result
Test Point
In ICE Mode,
Is the voltage between pin2
and pin6 of CON2 like as
below, while pushing the
ICE lever switch?
In CUBE Mode,
Is the voltage between pin2
and pin10 of CON2 like as
below, while pushing the
ICE lever switch?
115 V
pin2 To pin6
Pushing
Normal
Lever switch
0 ~ 2V
pin2 To pin6
Result
Test Point
Replace
Dispenser
PWB
(Position No:
155A)
Pin6 SB
Pin6 SB
Pin6 SB
Pin6 SB
Pin2 WH
Pin2 WH
Pin2 WH
Pin2 WH
Pin10 RD
Pin2 WH
Resistance of Cube solenoid
Resistance of Auger Motor
Output voltage of dispenser solenoid
Output voltage of auger motor
Содержание 795.78733.804
Страница 24: ...5 CIRCUIT DIAGRAM 24 ...
Страница 71: ... 71 7 9 Main PWB Assembly EBR41956404 CON1 CON2 CON3 CON4 CON5 CON6 CON9 ...