21
FIGURE 23.
Burner Cleaning
In the event your burner needs cleaning, following these
instructions:
If inspection of the burner shows that cleaning is required, turn
the gas control knob clockwise (
) to the “OFF” position,
depressing slightly.
NOTE: The knob cannot be turned from “PILOT” to “OFF”
unless knob is depressed slightly. DO NOT FORCE.
Loose deposits on or around the burner can be removed by
carefully using the hose of a vacuum cleaner inserted through
the access door of the water heater. If the burner needs to be
removed for additional cleaning, call the Sears Service Center
to remove and clean the burner and correct the problem that
required the burner to be cleaned.
Housekeeping
Vacuum around base of water heater for dust, dirt, and lint on a
regular basis.
INSTALLED IN SUITABLE AREA: To insure sufficient ventilation
and combustion air supply, proper clearances from the water
heater must be maintained.
See Facts to Consider About the
Location
section. Combustible materials such as clothing,
cleaning materials, or flammable liquids, etc. must not be placed
against or adjacent to the water heater because they could catch
on fire.
Anode Rod Inspection
The anode rod is used to protect the tank from corrosion. Most
hot water tanks are equipped with an anode rod. The submerged
rod deteriorates to protect the tank. Instead of corroding the
tank, water ions attack and eat away the anode rod. This does
not affect the water’s taste or color. The rod must be maintained
to keep the tank in operating condition.
Anode deterioration depends on water conductivity, not
necessarily water condition. A corroded or pitted anode rod
indicates high water conductivity and should be checked and/or
replaced more often than an anode rod that appears to be intact.
Replacement of a depleted anode rod can extend the life of
your water heater. Inspection should be conducted by calling
the Sears Service Center for an authorized contractor. At a
minimum, the anode(s) should be checked annually after the
warranty period.
Temperature-Pressure Relief Valve Operation
The temperature-pressure relief valve must be manually
operated at least once a year.
When checking the temperature-pressure relief valve operation,
make sure that (1) no one is in front of or around the outlet of
the temperature-pressure relief valve discharge line, and (2) that
the water discharge will not cause any property damage, as the
water may be extremely hot, see Figure 24.