25
Low heat, LP gas
The propane regulator assembly
incorporates an excess flow device
designed to supply the grill with
sufficient gas flow. Rapid changes in
pressure can trigger the excess flow
device, providing a low flame and
low temperature.
Please follow these instructions: 1. Make sure
all burners are “OFF”. 2. Open the tank
valve and wait 5 minutes. 3. Light the burner
one at a time following the lighting
instructions listed on the door liner
Sudden drop in gas
flow or low flame
1. Out of gas.
2. Excess flow valve tripped.
3. Vapor lock at coupling nut/LP
cylinder connection.
1. Check for gas in LP cylinder.
2. Turn off knobs, wait 30 seconds and light
grill. If flames are still low, turn off knobs
and LP cylinder valve. Disconnect regulator.
Reconnect regulator and leak test. Turn on LP
cylinder valve, wait 30 seconds and then
light grill.
3. Turn off knobs and LP cylinder valve.
Disconnect coupling nut from cylinder.
Reconnect and retry.
Cooking light will not
turn on.
1. No power supply.
2. Defective halogen bulb.
3. Internal wiring issue.
1. Check power supply and make sure
transformer is properly plugged in.
2. Replace the bulb.
3. Check the wiring connections under the
fire box. All wire connections must be tight. If
any wires are damaged they should be
replaced.
Problem
Possible Cause
Corrective Action
Содержание 139.20153510