Operating Instructions BA 77 600..A00 // Last updated: 13/03/2020 // Page 18 of 33
3.5 Set-up and start-up
Warning!
The functional check of the brake must not be performed unless the machine (e.g. motor) has been switched
off and secured against accidental or unintentional start-up.
3.5.1 Functional checks
The following checks must be carried out:
Check compliance with the specifications provided on the rating plate with respect to the mounting position
and protection class. After connection of the brake, an operational test must be performed to check that the
friction disc (5) runs smoothly. For this purpose, turn the shaft (while the brake is energised and the machine
(e.g. motor) is unpowered). Install the required guards and protections after completion of installation.
Specifications on the rating plate (subject to order, example type 77 60016A00):
Note:
The product number of the brake consists of the type number followed by the version number of
the spring-applied multiple-disc brake, e.g. 77 60016A00-0004.
Warning!
Before starting the machine (e.g. motor) test run without driven components, the feather key (if used) must be
secured in such a way that it cannot be hurled out. The shaft must not be exposed to load torques. Before the
machine (e.g. motor) is re-started, the brake must be de-energised.
Caution!
The brake surface temperature may rise to over 60°C. Heat-sensitive parts such as conventional cables or
electronic components must not be fixed to or be in contact with these surfaces. If necessary, suitable
protections and hand guards must be installed to avoid accidental contact with hot surfaces! If the shaft needs
to be turned during set-up operations while the machine (e.g. motor) is switched off, the brake must be released
electromagnetically or by means of the hand release lever (21).
Caution!
High-voltage tests performed during brake installation within an overall system or during start-up must be
carried out in such a way that damage to the built-in electronic accessories is avoided. The limits for high-
voltage tests and follow-up tests specified by DIN VDE 0580 must be observed.
Production id code
Nominal voltage / Coil voltage
Type number
Production id code
Production date (year and month, 3-digit)
Nominal voltage at AC current connection
CE mark
Voltage frequency
Nominal torque /
Transmissible torque
Offer drawing index
Version number (4-digit)