1.3.  OPERATION SAFETY

Never watch the arc without a face shield designed for arc welding!

The arc damages unprotected eyes!

The arc burns unprotected skin!

Be careful for reflecting radiation of arc!

Protect yourself and the surroundings against the arc and hot spray!

Remember general fire safety!

Pay attention to the fire safety regulations.  Welding is always classified as a fire risk operation.

Welding where there is flammable or explosive material is strictly forbidden.

If it is essential to weld in such an area remove inflammable material from the immediate vicinity of the welding 

site.

Fire extinguishers must always be on site where welding is taking place.

Note! Spars may cause fire many hours after completion of welding.

Watch out for the mains voltage!

Take care of the cables - the connection cable must not be compressed, touch sharp edges or hot work pieces.

Faulty cables are always a fire risk and highly dangerous.

Do not locate the welding machine on wet surfaces.

Do not take the welding machine inside the work piece (i.e. in containers, cars etc.)

Ensure that neither you nor gas bottles or electrical equipment are in contact with live wires or 

connections!

Do not use faulty welding cables.

Isolate yourself by using dry and not worn out protective clothes.

Do not weld on wet ground.

Do not place MIG gun or the welding cables on the power source or other electrical equipment.

Don’t press on MIG gun switch, if the gun is not directed towards work piece.

Watch out for the welding fumes!

Ensure that there is sufficient ventilation.

Follow special safety precautions when you weld metals which contain lead, cadmium, zinc, mercury or beryl-

lium.

Note the danger caused by special welding jobs!

Watch out for the fire and explosion danger when welding container type work pieces.

This equipment’s electromagnetic compatibility (EMC) is designed for use in an industrial  environment. 

Class A equipment is not intended for use in residential location where the electrical power is provided 

by the public low-voltage supply system.

Содержание KEMPOWELD 4200

Страница 1: ...KEMPOWELD 4200 4200W 5500W Operation instructions english Gebrauchsanweisung deutsch Gebruiksaanwijzing nederlands Manuel d utilisation fran ais 1922020E 0531...

Страница 2: ...LATION 8 2 1 Transport and lifting of the machine 8 2 2 Siting the machine 8 2 3 Connection to the mains supply 8 2 4 Welding and return current cables 8 2 5 Operation and use of controls 9 2 5 1 Main...

Страница 3: ...hine 1 2 PRODUCT INTRODUCTION The power sources Kempoweld 4200 and 4200W with wire feeder WIRE 400 make together 400 A MIG welding equipment which is suitable for heavy industrial use Kempoweld 5500W...

Страница 4: ...e risk and highly dangerous Do not locate the welding machine on wet surfaces Do not take the welding machine inside the work piece i e in containers cars etc Ensure that neither you nor gas bottles o...

Страница 5: ...d 4200W MSD 1 V A metering unit included in delivery of 5500W 1 4 2 Parts of cooling unit Kempoweld 4200W and 5500W S4 Main switch of cooling unit Sw1 Selecting switch for gun s cooling mode Sw2 Water...

Страница 6: ...selection panel or push pull gun X1 Control connector for push pull gun 1 5 3 Cooling unit connections 01 Return water connector for gun 02 Feed water connector for gun 04 Inlet of water hoses 1 5 4 R...

Страница 7: ...welding current cable 2 control cable 3 water hose blue marking 4 water hose red marking 5 shielding gas hose 6 protective hose Marking of interconnection cable item Example KW 50 5 WH KW identi cati...

Страница 8: ...coloured green yellow is coupled to connector marked with earth protection symbol If you are using 5 conduc tor cable you must cut the zero conductor to the level of the cable s protective shield Size...

Страница 9: ...circuit voltage lower 1 4 1 max 14 6 16 3 V 18 0 20 0 V 2 4 1 max 16 6 18 8 V 20 7 23 0 V 3 4 1 max 19 2 22 0 V 23 8 26 8 V 4 4 1 max 22 5 26 1 V 27 9 32 0 V higher 1 4 1 max 27 1 30 0 V 31 1 33 1 V...

Страница 10: ...al voltage due to cable etc losses Accuracy of voltage true value in respect to real value is 4 0 0 2 V by welding values according to the norm Accuracy of current true value in respect to real value...

Страница 11: ...ck entry of return water into the tank before welding Pilot lamps Pilot lamp for overheating Hw4 If the cooling water in the tank is overheating the thermal protection will stop the power source Opera...

Страница 12: ...ctions in the welding current circuit 4 MAINTENANCE The amount of use and the working environment should be taken into consideration when planning the frequency of maintenance of the machine Careful u...

Страница 13: ...class H 180 C H 180 C Operation temperature range 20 60 C 20 60 C Storage temperature range 40 60 C 40 60 C Degree of protection IP 23C IP 23C Cooling unit power 230 V 250 VA 230 V 250 VA Fuse delayed...

Страница 14: ...6255203MMT MMT 52W 4 5 m 6255204MMT KMP 400W 6 m 6257406 KMP 400W 10 m 6257410 WS 42W Al 1 2 1 6 6 m 6254206A12 WS 42W SS 1 0 6 m 6254206S10 WS 42W SS 1 2 6 m 6254206S12 WS 42W Al 1 2 1 6 8 m 6254208...

Страница 15: ...tee does not cover direct or indirect travelling costs daily allowances or accommodation Note Under the terms of guarantee welding torches and their consumables feeder drive rolls and feeder guide tub...

Страница 16: ...076 5717 750 Telefax 076 5716 345 e mail sales nl kemppi com KEMPPI UK Ltd Martti Kemppi Building Fraser Road Priory Business Park BEDFORD MK443WH ENGLAND Tel 0845 6444201 Fax 0845 6444202 e mail sale...