Kemppi KEMPOWELD 4200 Скачать руководство пользователя страница 11

KEMPOWELD 4200, 4200W, 5500W / 0531 – 11

© KEMPPI OY

2.7.2.  Operation switches

In zero (O) position of the power source´s main switch also all operations of the cooling unit are stopped.

Cooling unit´s main switch O / I

The electric supply for the pump motor is switched on by main switch key 

O / I

, where the pilot lamp indicates 

the standby state 

I

. In zero (

O

) position of the main switch the pump motor cannot get started, but the switches 

and pilot lamps are operating.

Fuse (F2)

The fuse on the front wall of the cooling unit is short-circuit protection. Use the fuse size and type according to 

markings. If the fuse is blowing again, send the unit to service.

Selecting switch for gun’s cooling mode (Sw1)

The Kempoweld equipment are suitable to be used with both air- and water-cooled guns. Select cooling mode and 

correct use and protection functions with switch on the cooling unit´s panel.

If your choice is 

GAS

, but you are using water-cooled gun, no protection is operating. The pilot lamp is illuminated 

in position I of the cooling unit´s main switch. However, the control does not start the pump.

The wrong choice will destroy the gun in short time!

If your choice is   (water), but you are using air-cooled gun, the pump gets started by pressing on the trigger, if 

the cooling unit´s main switch is in position I.

Test switch (Sw5)

By TEST switch on the panel of the cooling unit you can circulate water without starting welding. It is used for 

filling the gun and interconnection cable with cooling water before starting welding. By disturbance situations you 

can always test the water circulation. Always check entry of return water into the tank before welding!

Pilot lamps

Pilot lamp for overheating (Hw4)

If the cooling water in the tank is overheating, the thermal protection will stop the power source. Operation of the 

cooling unit is continued for ca. 5 - 7 min automatically. The pilot lamp will switch off after the water in the tank 

has cooled down, after which the welding will start from the gun triggering.

Pilot lamp for lacking liquid pressure (Hw3)

If the pump does not step up sufficient supply pressure, e.g. when the water is running out or by disturbances in 

the pump, the whole equipment will stop after ca. 5 s and the red pilot lamp illuminates. Check the equipment like 

by the installation. See paragraph for Operation disturbances.

Operating control

The water circulation gets automatically started, when you are pressing on the gun trigger. The post-circulation 

of water will continue for ca. 5–7 min. after the weld end. The time is always counted from the latest trigger re-

lease.

3.  OPERATION DISTURBANCES

By the operation or functional disturbances take the measures according to the following list.

If the disturbance cannot be eliminated, check the equipment according to the paragraphs Installation and 

Maintenance, and take contact with Authorized Kemppi repair shop.

The pump does not get started by test switch:

–  check the fuse on the front plate of the cooling unit

–  check the fuse on the rear plate of the power source

–  check position for cooling mode selecting switch

–  check positions for main switches

The water does not circulate by lever switch:

–  check the tank filling volume

–  disconnect the connector for the return water hose of the gun from the rear wall of the cooling unit and use 

thet test switch

  If the water is pumped, close the connector and run again by the test switch

Содержание KEMPOWELD 4200

Страница 1: ...KEMPOWELD 4200 4200W 5500W Operation instructions english Gebrauchsanweisung deutsch Gebruiksaanwijzing nederlands Manuel d utilisation fran ais 1922020E 0531...

Страница 2: ...LATION 8 2 1 Transport and lifting of the machine 8 2 2 Siting the machine 8 2 3 Connection to the mains supply 8 2 4 Welding and return current cables 8 2 5 Operation and use of controls 9 2 5 1 Main...

Страница 3: ...hine 1 2 PRODUCT INTRODUCTION The power sources Kempoweld 4200 and 4200W with wire feeder WIRE 400 make together 400 A MIG welding equipment which is suitable for heavy industrial use Kempoweld 5500W...

Страница 4: ...e risk and highly dangerous Do not locate the welding machine on wet surfaces Do not take the welding machine inside the work piece i e in containers cars etc Ensure that neither you nor gas bottles o...

Страница 5: ...d 4200W MSD 1 V A metering unit included in delivery of 5500W 1 4 2 Parts of cooling unit Kempoweld 4200W and 5500W S4 Main switch of cooling unit Sw1 Selecting switch for gun s cooling mode Sw2 Water...

Страница 6: ...selection panel or push pull gun X1 Control connector for push pull gun 1 5 3 Cooling unit connections 01 Return water connector for gun 02 Feed water connector for gun 04 Inlet of water hoses 1 5 4 R...

Страница 7: ...welding current cable 2 control cable 3 water hose blue marking 4 water hose red marking 5 shielding gas hose 6 protective hose Marking of interconnection cable item Example KW 50 5 WH KW identi cati...

Страница 8: ...coloured green yellow is coupled to connector marked with earth protection symbol If you are using 5 conduc tor cable you must cut the zero conductor to the level of the cable s protective shield Size...

Страница 9: ...circuit voltage lower 1 4 1 max 14 6 16 3 V 18 0 20 0 V 2 4 1 max 16 6 18 8 V 20 7 23 0 V 3 4 1 max 19 2 22 0 V 23 8 26 8 V 4 4 1 max 22 5 26 1 V 27 9 32 0 V higher 1 4 1 max 27 1 30 0 V 31 1 33 1 V...

Страница 10: ...al voltage due to cable etc losses Accuracy of voltage true value in respect to real value is 4 0 0 2 V by welding values according to the norm Accuracy of current true value in respect to real value...

Страница 11: ...ck entry of return water into the tank before welding Pilot lamps Pilot lamp for overheating Hw4 If the cooling water in the tank is overheating the thermal protection will stop the power source Opera...

Страница 12: ...ctions in the welding current circuit 4 MAINTENANCE The amount of use and the working environment should be taken into consideration when planning the frequency of maintenance of the machine Careful u...

Страница 13: ...class H 180 C H 180 C Operation temperature range 20 60 C 20 60 C Storage temperature range 40 60 C 40 60 C Degree of protection IP 23C IP 23C Cooling unit power 230 V 250 VA 230 V 250 VA Fuse delayed...

Страница 14: ...6255203MMT MMT 52W 4 5 m 6255204MMT KMP 400W 6 m 6257406 KMP 400W 10 m 6257410 WS 42W Al 1 2 1 6 6 m 6254206A12 WS 42W SS 1 0 6 m 6254206S10 WS 42W SS 1 2 6 m 6254206S12 WS 42W Al 1 2 1 6 8 m 6254208...

Страница 15: ...tee does not cover direct or indirect travelling costs daily allowances or accommodation Note Under the terms of guarantee welding torches and their consumables feeder drive rolls and feeder guide tub...

Страница 16: ...076 5717 750 Telefax 076 5716 345 e mail sales nl kemppi com KEMPPI UK Ltd Martti Kemppi Building Fraser Road Priory Business Park BEDFORD MK443WH ENGLAND Tel 0845 6444201 Fax 0845 6444202 e mail sale...

Отзывы: