2.4.5. Adjustment for arc roughness

Arc roughness is adjusted by connecting the return current cable to the applicable one of the two dix-connectors 

on the front plate.
The connector marked with shorter symbol gives a rougher arc, which is used for welding of thin sheets and ferrous 

metals by 0.6 - 1.0 mm wires and especially with CO² shielding gas. The connector marked with longer symbol 

is suitable for thicker wires and especially for aluminium and stainless materials. The most suitable roughness is, 

however, most dependent on the welding case. You will find the best position by testing the different positions.

2.4.6. Operation of cooling fan

The cooling fan on the rear plate of the Kempoweld 3200 equipment is started and stopped according to use. The 

cooling fan is controlled by the gun trigger and control circuits. The cooling fan is started after ca. 15 s after weld 

start and stopped after ca. 10 min after weld end or release of the overheat protection.

Do not switch off the unit with the main switch before the cooling fan has automatically stopped.

By open circuit the cooling fan does not get started.

2.4.7. Accessory drawer

In the accessory drawer in the cover part of the unit are by delivery the plastic guide tubes needed for welding of 

aluminium and stainless steels. In the drawer are also the screw and the insulation bushings needed for locking of 

rotation of the wire feeder Kempoweld WIRE 400.

2.4.8. Adjustment for wire feed

The wire feed is adjusted from the potentiometer on the control panel of 

the wire feeder unit Kempoweld WIRE 400. The adjustment has been 

described in the operation instructions of the wire feeder unit.

2.5. VOLT / AMPERE METERING UNIT MSD-1

For the mounting of the MSD-1 remove the cover plate on the front panel of the unit. The connector of flat cable 

fastened to the cover plate is connected to the corresponding connector of the MSD-1. From the metering unit you 

can with lever switch select momentary display for either voltage or current. By open circuit only voltage value is 

displayed, because there is no welding current present.

The voltage value is the voltage between the unit´s welding connectors or terminal voltage. The value of the open 

circuit voltage has not very much importance for the welding, so that the display of the metering unit is adjusted 

according to the welding situation. The display of the open circuit voltage differs 2-3 V from the true voltage. 

During welding the terminal voltage is varying and the arc voltage differs from the terminal voltage due to cable 

etc. losses. Accuracy of voltage true value in respect to real value is ±4,0 %, ±0,2 V by welding values according 

to the norm.

Accuracy of current true value in respect to real value is ±2,5 %, ±2 A.

The metering unit does not show wire feed values.

The MSD-1 does not need any calibration in the Kempoweld power source.

The switch positions: V = voltage display, A = current display.

2.6. COOLING UNIT

Kempoweld 3200W power source has inbuilt cooling unit.

2.6.1. Installation of cooling

The cooling unit is connected to the gun by means of water hoses, which are mounted to the wire feeder unit. The 

interconnection cable contains also the water hoses, which are mounted to the gun through the wire feeder unit 

without any extension parts. See operation instruction for Kempoweld WIRE feeders.

Before connection check that in the hoses are no dirt, metal powder, rubber waste etc. The connectors for hoses 

and cooling unit are marked with red or blue identification rings or spots. Blue is colour for water supplied from 

cooling unit to gun and red is colour for water returning back from gun to cooling unit.

Содержание KEMPOWELD 3200

Страница 1: ...KEMPOWELD 3200 3200W Operation instructions english Gebrauchsanweisung deutsch Gebruiksaanwijzing nederlands Manuel d utilisation fran ais 1922010E 0543...

Страница 2: ...LLATION 6 2 1 SITING THE MACHINE 6 2 2 CONNECTION TO THE MAINS SUPPLY 6 2 3 WELDING AND RETURN CURRENT CABLES 7 2 4 OPERATION AND USE OF CONTROLS 7 2 4 1 MAIN SWITCH S1 7 2 4 2 ADJUSTMENT OF WELDING V...

Страница 3: ...WIRE 400 wire feeder unit equipped also with interconnection cable and push pull gun KMW timer controls continuous spot and cycle arc welding Accessory unit KMW sync is needed for connection and use o...

Страница 4: ...drawer MSD 1 V A metering unit accessory 1 4 2 Parts of cooling unit Kempoweld 3200W S4 Main switch of cooling unit Sw1 Selecting switch for gun s cooling mode Sw2 Water cooling test switch Hw4 Pilot...

Страница 5: ...n panel or push pull gun X1 Control connector for push pull gun 1 5 3 Cooling unit connections 01 Return water connector for gun 02 Feed water connector for gun 04 Inlet of water hoses 1 5 4 Rear pane...

Страница 6: ...Kempoweld power source is equipped with 5 m supply cable without plug The mains cable is according to the marking H07RN F of the norm CENELEC HD22 The mains cable must be changed if it does not meet...

Страница 7: ...switch on and switch off the machine from the main switch Never use the mains plug for switching on or switching off the units and equipment 2 4 2 Adjustment of welding voltage Table of adjustments sw...

Страница 8: ...the mounting of the MSD 1 remove the cover plate on the front panel of the unit The connector of at cable fastened to the cover plate is connected to the corresponding connector of the MSD 1 From the...

Страница 9: ...ecting switch for gun s cooling mode Sw1 The Kempoweld equipment are suitable to be used with both air and water cooled guns Select cooling mode and correct use and protection functions with switch on...

Страница 10: ...is stopped check the cooling water volume and return ow to the tank in the system are air bubbles or leakages especially check the connections of the cooling unit the pressure switch set value ca 1 b...

Страница 11: ...ts or parts in bad connection are replaced by new ones Maintenance testing Operation and performance values of the equipment are checked and adjusted when necessary by means of test equipment 5 DISPOS...

Страница 12: ...06 KMP 400W 10 m 6257410 WS 30W Al 1 2 1 6 6 m 6253046A12 WS 30W SS 1 0 6 m 6253046S10 WS 30W SS 1 2 6 m 6253046S12 WS 30W Al 1 2 1 6 8 m 6253048A12 WS 30W SS 1 0 8 m 6253048S10 WS 30W SS 1 2 8 m 6253...

Страница 13: ...ction to wire feeder unit 30 V 250 VA Fuse delayed 8 A Loading capacity 40 ED 320 A 32 V nominal values 60 ED 265 A 27 V 100 ED 205 A 24 V Control range 40 steps 40 320 A 15 32 V Open circuit voltage...

Страница 14: ...does not cover direct or indirect travelling costs daily allowances or accommodation Note Under the terms of guarantee welding torches and their consumables feeder drive rolls and feeder guide tubes...

Страница 15: ...DERLAND Tel 31 0 76 5717750 Telefax 31 0 76 5716345 e mail sales nl kemppi com KEMPPI UK Ltd Martti Kemppi Building Fraser Road Priory Business Park BEDFORD MK443WH ENGLAND Tel 0845 6444201 Fax 0845 6...

Отзывы: