KEMPOWELD 3200, 3200W / 0543 – 13
© KEMPPI OY
7. TECHNICAL DATA
The products meet conformity requirements for CE marking.
Kempoweld
3200
3200W
Connection voltage
3 ~ 400 V
380 V -10 % ... 415 V +6 %
3 ~ 230 V
220 V -10 % ... 240 V +6 %
Connection capacity
40 % ED
13,6 kVA
230 V / 400 V
60 % ED
10,0 kVA
100 % ED
6,6 kVA
Main cable / fuses
220 - 240 V
4 x 2,5 mm² / 20 A delayed
380 - 415 V
4 x 2,5 mm² / 16 A delayed
Connection to wire feeder unit
30 V / 250 VA
Fuse delayed
8 A
Loading capacity
40 % ED
320 A / 32 V
(nominal values)
60 % ED
265 A / 27 V
100 % ED
205 A / 24 V
Control range 40 steps
40 - 320 A / 15 - 32 V
Open circuit voltage 40 steps
15 - 40 V
Open circuit power
< 50 W
Efficiency
320 A / 32 V
75 %
Power factor
320 A / 32 V
0,95
Temperature class
H (180 ºC)
Operation temperature range
-20...+60 °C
Storage temperature range
-40...+60 °C
Degree of protection
IP 23C
Cooling unit power
- - -
230 V / 250 VA
Fuse delayed
- - -
2 A
External dimensions
lenght
990 mm
990 mm
width
530 mm
530 mm
height
880 mm
1090 mm
Weight
106 kg
118 kg