3. OPERATION DISTURBANCES

By the operation or functional disturbances take the measures according to the following list.
If  the  disturbance  cannot  be  eliminated,  check  the  equipment  according  to  the  paragraphs  Installation  and 

Maintenance, and take contact with Authorized Kemppi repair workshop.

The pump does not get started by test switch:

–  check the fuse on the front plate of the cooling unit
–  check the fuse on the rear plate of the power source
–  check position for cooling mode selecting switch
–  check positions for main switches

The water does not circulate by lever switch:

–  check the tank filling volume
–  disconnect the connector for the return water hose of the gun from the rear wall of the cooling unit and use 

thet test switch

  If the water is pumped, close the connector and run again by the test switch
  A good tip: Blow compressed air into the tank; closing the filling opening by hand is enough.

The water is pumping, but does not return back to the tank or the return flow is weak:

–  filling of interconnection cable can take several minutes
–  if you have lifted the gun or interconnection cable for the filling time many meters higher than the power 

source, the filling will happen considerably slower. Fill the hoses on the floor position.

–  check the whole flowing line connector by connector

The water is pumping, but during welding the red pilot lamp for the water pressure is lit and 

the equipment is stopped:

–  check the cooling water volume and return flow to the tank
–  in the system are air bubbles or leakages, especially check the connections of the cooling unit.
–  the pressure switch set value (ca. 1 bar) is unsuitable for the gun you are using:
1. Open the side plate. In the middle at the upper end of the pressure guard connected to the pump is the 

adjusting screw for limit value.

2. Use the pump during the adjustment by the test switch.
3. After ca. 5 s use twist the screw carefully until the pilot lamp is switched off.
4. Check the result by welding.
5. If the adjustment and checkings do not eliminate the disturbance, take contact with the Authorized Kemppi 

repair workshop.

During welding the yellow pilot lamp for overheating is lit and the equipment is stopped:

–  release the trigger. When the lamp is switched off, the operation has been reset automatically
–  check if the gun is suitable for power you are using
–  check condition of connectors and connections in the welding current circuit

4. MAINTENANCE

The amount of use and the working environment should be taken into consideration when planning the frequency of 

maintenance of the machine. Careful use and preventive maintenance will help to ensure trouble-free operation.

Cables

Check the condition of welding and connection cables daily. Do not use faulty cables! Make sure that the mains 

connection cables in use are safe and according to regulations! The repair and mounting of mains connection cables 

should be carried out only by an authorized electrician.

Power source

NOTE!

 Disconnect the plug of the power source from the mains socket before removing the cover plate.

Содержание KEMPOWELD 3200

Страница 1: ...KEMPOWELD 3200 3200W Operation instructions english Gebrauchsanweisung deutsch Gebruiksaanwijzing nederlands Manuel d utilisation fran ais 1922010E 0543...

Страница 2: ...LLATION 6 2 1 SITING THE MACHINE 6 2 2 CONNECTION TO THE MAINS SUPPLY 6 2 3 WELDING AND RETURN CURRENT CABLES 7 2 4 OPERATION AND USE OF CONTROLS 7 2 4 1 MAIN SWITCH S1 7 2 4 2 ADJUSTMENT OF WELDING V...

Страница 3: ...WIRE 400 wire feeder unit equipped also with interconnection cable and push pull gun KMW timer controls continuous spot and cycle arc welding Accessory unit KMW sync is needed for connection and use o...

Страница 4: ...drawer MSD 1 V A metering unit accessory 1 4 2 Parts of cooling unit Kempoweld 3200W S4 Main switch of cooling unit Sw1 Selecting switch for gun s cooling mode Sw2 Water cooling test switch Hw4 Pilot...

Страница 5: ...n panel or push pull gun X1 Control connector for push pull gun 1 5 3 Cooling unit connections 01 Return water connector for gun 02 Feed water connector for gun 04 Inlet of water hoses 1 5 4 Rear pane...

Страница 6: ...Kempoweld power source is equipped with 5 m supply cable without plug The mains cable is according to the marking H07RN F of the norm CENELEC HD22 The mains cable must be changed if it does not meet...

Страница 7: ...switch on and switch off the machine from the main switch Never use the mains plug for switching on or switching off the units and equipment 2 4 2 Adjustment of welding voltage Table of adjustments sw...

Страница 8: ...the mounting of the MSD 1 remove the cover plate on the front panel of the unit The connector of at cable fastened to the cover plate is connected to the corresponding connector of the MSD 1 From the...

Страница 9: ...ecting switch for gun s cooling mode Sw1 The Kempoweld equipment are suitable to be used with both air and water cooled guns Select cooling mode and correct use and protection functions with switch on...

Страница 10: ...is stopped check the cooling water volume and return ow to the tank in the system are air bubbles or leakages especially check the connections of the cooling unit the pressure switch set value ca 1 b...

Страница 11: ...ts or parts in bad connection are replaced by new ones Maintenance testing Operation and performance values of the equipment are checked and adjusted when necessary by means of test equipment 5 DISPOS...

Страница 12: ...06 KMP 400W 10 m 6257410 WS 30W Al 1 2 1 6 6 m 6253046A12 WS 30W SS 1 0 6 m 6253046S10 WS 30W SS 1 2 6 m 6253046S12 WS 30W Al 1 2 1 6 8 m 6253048A12 WS 30W SS 1 0 8 m 6253048S10 WS 30W SS 1 2 8 m 6253...

Страница 13: ...ction to wire feeder unit 30 V 250 VA Fuse delayed 8 A Loading capacity 40 ED 320 A 32 V nominal values 60 ED 265 A 27 V 100 ED 205 A 24 V Control range 40 steps 40 320 A 15 32 V Open circuit voltage...

Страница 14: ...does not cover direct or indirect travelling costs daily allowances or accommodation Note Under the terms of guarantee welding torches and their consumables feeder drive rolls and feeder guide tubes...

Страница 15: ...DERLAND Tel 31 0 76 5717750 Telefax 31 0 76 5716345 e mail sales nl kemppi com KEMPPI UK Ltd Martti Kemppi Building Fraser Road Priory Business Park BEDFORD MK443WH ENGLAND Tel 0845 6444201 Fax 0845 6...

Отзывы: