6. ORDERING 

NUMBERS

Wire feed units

Feed 420R wire feed control unit 

 

6236420

Feed 120R wire feed unit 

 

 

6236120

Accessories of Feed 420R

Sync 

400 

    6263120

GG 

400     6237405

Wire 

reel 

hub 

    4289880

Power sources

Kempomig 4000R 

 

6227400R

Kempomig 4000WR 

 

6227400WR

MSD 

     6185666

Cabels

Voltage monitor cable   

 

 

4288700

Branch 

connector 

   9771637

Intermediate cable assembly 

 

5 m 

6260421

 

 

    10 

6260425

Earth cable  

 

50 mm

5 m 

6184511

 

 

  50 

mm

10 m 

6184512

Earth cable 

 

70 mm

5 m 

6184711

 

 

  70 

mm

10 m 

6184712

MIG guns for robotic and automated welding

MT38M  3,0 

  6253038

MT-51MW 

 

1,5 m / SK 

 

6255156

MT-51MW 

 

1,5 m / K30 

 

6255157

MT-51MW 

 

3,0 m / SK 

 

6255158

MT-51MW 

 

3,0 m / K30 

 

6255159

Interconnection cables

Interconnection cables Kempomig 4000R, 4000WR / Feed 420R

KW 

50-1.3-GH     6260350

Multimig 

70-11-GH 

   6260182

Return current cable

5 m - 50 mm

 

    6184511

Содержание KempoMig FEED 120R

Страница 1: ...Operation instructions english Gebrauchsanweisung deutsch Gebruiksaanwijzing nederlands Manuel d utilisation fran ais 1922420E...

Страница 2: ...sure 11 2 10 Adjustment of tightness of wire reel brake accessory 11 2 11 Ground cable 12 2 12 Shield gas 12 2 12 1 Installing gas bottle 12 3 FEED 420R FUNCTIONS 13 3 1 Function panel 13 3 2 Selectio...

Страница 3: ...In this document for danger to life or injury the following symbol is used Read the warning texts carefully and follow the instructions Please also study the Operation safety instructions and respect...

Страница 4: ...out from sparks even several hours after the welding work has been finished Mains voltage Never take welding machine inside a work piece eg container or truck Do not place welding machine on a wet sur...

Страница 5: ...eeding control unit Welding current output connector Voltage monitoring connector Control panel Wire inch Gas purge Robot controller connector Control cable connector to Feed 120R Gas snap connectors...

Страница 6: ...20R wire feeder Connector for motorised gun Welding current cable connector Gas purge Wire inch Snap connector for air blast Euro connector for robot gun Snap connectors for cooling liquid Control cab...

Страница 7: ...Kempomig Feed 420R 120R 0429 7 COPYRIGHT KEMPPI OY Feed 120R KEMPOMIG4000WR MSD1 Feed 420R SYNC400 GG400 2 2 UNITS ACCESSORIES CABLES Intermediate cable Kempomig Feed Branch cable Intermediate cable...

Страница 8: ...8 Kempomig Feed 420R 120R 0429 COPYRIGHT KEMPPI OY 2 3 PARTS OF WIRE FEED MECHANISM...

Страница 9: ...feed disturbances 4 If you mount the Feed 420R onto boom see that the wire feeder unit s chassis is without galvanic contact to boom 5 Max wire feed speed When the unit is delivered the max wire feed...

Страница 10: ...ted by moving selecting washer 28 from one side to another in feed roll Feed rolls and wire guide tubes have colour codes in order to make identification easier see table on page 8 feed rolls colour f...

Страница 11: ...that the wire does not spill from the reel to sides Straighten the wire at a length of about 20 cm and see that its end has no sharp edges file off if necessary A sharp edge may damage the wire guide...

Страница 12: ...heating of connectors and insulations Make sure that the welding gun in your use is designed for max welding current needed Never use a damaged welding gun 2 12 SHIELD GAS Handle gas bottle with care...

Страница 13: ...e contents of the bottle The bottle should be filled when the bottle pressure is 2 bar 8 Open needle valve if there is one in the regulator 9 Turn regulation screw B until hose pressure meter G shows...

Страница 14: ...f steel 3 5 SELECTING SWITCH OF MAIN CONTROLS Remote control basic controls are made from robotic control unit Local control basic controls are made from potentiometers of the panel 3 6 DISPLAY OF SEL...

Страница 15: ...100 CO2 2 1 21 0 8 Fe Ar15 25 CO2 2 2 22 1 0 Fe Ar15 25 CO2 2 3 23 1 2 Fe Ar15 25 CO2 3 1 no program 3 2 no program 3 3 33 1 2 Metal cored wire Ar15 25 CO2 4 1 no program 4 2 no program 4 3 43 1 2 Rut...

Страница 16: ...S 4 1 SYNCHRONIZING UNIT SYNC 400 By means of Sync 400 you can connect the push pull gun to the Feed 420R wire feeding control unit Push pull gun is most commonly used for feeding of aluminium wires P...

Страница 17: ...Excessive wear of grooves causes wire feed problems Wire guide tubes Badly worn feed rolls and wire guide tubes should be discarded Wire guide tube in the gun should be set as close to the feed rolls...

Страница 18: ...monitor cable 4288700 Branch connector 9771637 Intermediate cable assembly 5 m 6260421 10 m 6260425 Earth cable 50 mm2 5 m 6184511 50 mm2 10 m 6184512 Earth cable 70 mm2 5 m 6184711 70 mm2 10 m 61847...

Страница 19: ...ter of feed roll 32 mm Wire feed speed I 0 18 m min II 0 25 m min Filler wires Fe Ss 0 6 1 2 mm Filler wire 0 8 1 6 mm Al 1 0 1 6 mm Wire reel max weight 20 kg max size 300 mm Gun connector Euro Opera...

Страница 20: ...td Martti Kemppi Building Fraser Road Priory Business Park BEDFORD MK443WH ENGLAND Tel 0845 6444201 Fax 0845 6444202 e mail sales uk kemppi com KEMPPI FRANCE S A S A au capital de 5 000 000 F 65 Avenu...

Отзывы: