Kemppi KempoMig FEED 120R Скачать руководство пользователя страница 14

14 – Kempomig Feed 420R, 120R / 0429

© 

COPYRIGHT

 

KEMPPI

 

OY

1

2

3

4

5 6 7

8

9

H

L

1

3

2

(1) Wire feed speed adjustment by MIG / MAG. Welding power adjustment by synergic 1-knob 
MIG.

(2) Welding voltage adjustment by MIG/MAG. Arc length adjustment by synergic 1-knob MIG. 
(3) Wire feed speed in m/min, plate thickness display in mm. Note! you can select the plate 
thickness display only by synergic 1-knob MIG.
With the selecting switch (4) is selected which variable is visible in the display. The plate 
thickness display is an informative thickness display for welding plates when making horizontal 
vertical fi llet welds.

(5) Set value display for welding voltage by MIG and 1-knob MIG, V.
This display is also used as display for MIG welding dynamics, -9...0...9.

3.4. 

MIG WELDING DYNAMICS ADJUSTMENT

With MIG welding dynamics adjustment, you can infl uence welding stability 
and spatter amount. Zero setting is recommended basic setting. Values –> 
min (-1...-9), softer arc for reduced spatter amount. Values –> max (1...9), 
harder arc for increased stability and when 100 % CO

2

 shielding gas is used 

in welding of steel.

3.5. 

SELECTING SWITCH OF MAIN CONTROLS

Remote control, basic controls are made from robotic control unit.

Local control, basic controls are made from potentiometers of the panel.

3.6. 

DISPLAY OF SELECTED 1-KNOB MIG SYNERGETIC 

 PROGRAM

The display shows number for 1-knob MIG program which has been 
selected with selecting switches on the synergy panel. If on display is visible 
´– –´, you have not selected any 1-knob MIG program. Then welding is 
prevented. By normal MIG / MAG welding the display is black.

3.7. 

1-KNOB MIG SYNERGY PANEL

Burn back time adjustment

Material 
choice switch

Wire diameter 
choice switch

Selecting switch for 
crater fi lling

1-MIG synergy panel is in the reel cabinet. On the MIG synergy panel there are selecting 
switches for 1-knob MIG synergetic curve, selecting switch for 1-knob MIG crater fi lling as 
well as potentiometer for burn back time adjustment.

3.8. 

BURN BACK TIME ADJUSTMENT

Burn back time is adjusted steplessly. The value for burn back time is selected according to 
material in question so that the fi ller wire will not stick on the weld piece at the weld end, and 
also that there will not become too big a ”ball” at the wire tip. The burn back time is changed 
automatically as correct according to changes of the wire feed speed.

Содержание KempoMig FEED 120R

Страница 1: ...Operation instructions english Gebrauchsanweisung deutsch Gebruiksaanwijzing nederlands Manuel d utilisation fran ais 1922420E...

Страница 2: ...sure 11 2 10 Adjustment of tightness of wire reel brake accessory 11 2 11 Ground cable 12 2 12 Shield gas 12 2 12 1 Installing gas bottle 12 3 FEED 420R FUNCTIONS 13 3 1 Function panel 13 3 2 Selectio...

Страница 3: ...In this document for danger to life or injury the following symbol is used Read the warning texts carefully and follow the instructions Please also study the Operation safety instructions and respect...

Страница 4: ...out from sparks even several hours after the welding work has been finished Mains voltage Never take welding machine inside a work piece eg container or truck Do not place welding machine on a wet sur...

Страница 5: ...eeding control unit Welding current output connector Voltage monitoring connector Control panel Wire inch Gas purge Robot controller connector Control cable connector to Feed 120R Gas snap connectors...

Страница 6: ...20R wire feeder Connector for motorised gun Welding current cable connector Gas purge Wire inch Snap connector for air blast Euro connector for robot gun Snap connectors for cooling liquid Control cab...

Страница 7: ...Kempomig Feed 420R 120R 0429 7 COPYRIGHT KEMPPI OY Feed 120R KEMPOMIG4000WR MSD1 Feed 420R SYNC400 GG400 2 2 UNITS ACCESSORIES CABLES Intermediate cable Kempomig Feed Branch cable Intermediate cable...

Страница 8: ...8 Kempomig Feed 420R 120R 0429 COPYRIGHT KEMPPI OY 2 3 PARTS OF WIRE FEED MECHANISM...

Страница 9: ...feed disturbances 4 If you mount the Feed 420R onto boom see that the wire feeder unit s chassis is without galvanic contact to boom 5 Max wire feed speed When the unit is delivered the max wire feed...

Страница 10: ...ted by moving selecting washer 28 from one side to another in feed roll Feed rolls and wire guide tubes have colour codes in order to make identification easier see table on page 8 feed rolls colour f...

Страница 11: ...that the wire does not spill from the reel to sides Straighten the wire at a length of about 20 cm and see that its end has no sharp edges file off if necessary A sharp edge may damage the wire guide...

Страница 12: ...heating of connectors and insulations Make sure that the welding gun in your use is designed for max welding current needed Never use a damaged welding gun 2 12 SHIELD GAS Handle gas bottle with care...

Страница 13: ...e contents of the bottle The bottle should be filled when the bottle pressure is 2 bar 8 Open needle valve if there is one in the regulator 9 Turn regulation screw B until hose pressure meter G shows...

Страница 14: ...f steel 3 5 SELECTING SWITCH OF MAIN CONTROLS Remote control basic controls are made from robotic control unit Local control basic controls are made from potentiometers of the panel 3 6 DISPLAY OF SEL...

Страница 15: ...100 CO2 2 1 21 0 8 Fe Ar15 25 CO2 2 2 22 1 0 Fe Ar15 25 CO2 2 3 23 1 2 Fe Ar15 25 CO2 3 1 no program 3 2 no program 3 3 33 1 2 Metal cored wire Ar15 25 CO2 4 1 no program 4 2 no program 4 3 43 1 2 Rut...

Страница 16: ...S 4 1 SYNCHRONIZING UNIT SYNC 400 By means of Sync 400 you can connect the push pull gun to the Feed 420R wire feeding control unit Push pull gun is most commonly used for feeding of aluminium wires P...

Страница 17: ...Excessive wear of grooves causes wire feed problems Wire guide tubes Badly worn feed rolls and wire guide tubes should be discarded Wire guide tube in the gun should be set as close to the feed rolls...

Страница 18: ...monitor cable 4288700 Branch connector 9771637 Intermediate cable assembly 5 m 6260421 10 m 6260425 Earth cable 50 mm2 5 m 6184511 50 mm2 10 m 6184512 Earth cable 70 mm2 5 m 6184711 70 mm2 10 m 61847...

Страница 19: ...ter of feed roll 32 mm Wire feed speed I 0 18 m min II 0 25 m min Filler wires Fe Ss 0 6 1 2 mm Filler wire 0 8 1 6 mm Al 1 0 1 6 mm Wire reel max weight 20 kg max size 300 mm Gun connector Euro Opera...

Страница 20: ...td Martti Kemppi Building Fraser Road Priory Business Park BEDFORD MK443WH ENGLAND Tel 0845 6444201 Fax 0845 6444202 e mail sales uk kemppi com KEMPPI FRANCE S A S A au capital de 5 000 000 F 65 Avenu...

Отзывы: