13
A5 MIG Rail System
© Kemppi Oy 2021
R01
OPERA
TING M
ANU
AL
3.3 Remote control unit
3.3.1 Basic functions
1. Press Stop to extinguish the arc and stop the
carriage.
2. Hold down ALT to activate the orange marked
secondary functions of the buttons.
3. CH first press: Start test run (arc off) with
programmed speed and weaving.
4. CH second press during welding/running:
Carriage speed increases (up), or decreases
(down).
5. CH long press: High-speed transportation (arc
off).
Moves the centerline of weaving or welding to the
button's direction
The direction is determined when facing the carriage
control panel. If you are standing on the other side of the
carriage, the directions are reversed
Increases or decreases the weaving width by 1 mm per
press of button (0.5 mm on both sides).
3.3.2 Alt functions
Starts welding to the button’s direction. If on test run,
the arc ignites.
Activate the next (up) or previous (down) program,
including memory channel, if CH REMOTE is ON at the
wire feeder.
Increase (+) or decrease (-) the arc voltage
Increase (+) or decrease (-) the wire feed speed
Fine-adjustment of voltage and wire feed only works
when CH REMOTE is OFF at the wire feeder.
Stop
terminates the operation of the carriage and stops
welding.