7.4 Troubleshooting
Problem
Possible Cause
Corrective Action
Not all smoke is
captured.
Distance from the
extraction hood to weld too
great.
Move extraction hood
closer.
Clean air outlet covered
Keep clean air outlet free.
Signal horn sounds
Insufficient extraction,
butterfly valve in the
extraction hood closed.
Open butterfly valve in the
extraction hood fully.
Filter inserts saturated
Change the filter inserts.
Dust comes out on the
clean air side.
Filter inserts damaged
Change the filter inserts.
Motor protection relay
triggers
Motor blocked
Ask an electrician to check
it.
The motor protection relay
(F4) has to be manually
reset.
Unit does not start.
No mains voltage
available.
Ask an electrician to check
it.
Start-stop sensor
connected but no current
detected (welding has not
started)
Start welding