MODEL KEI-200A SPC DIGITAL INCLINOMETER
96-014.doc
Page 8 of 8
47650 CLIPPER DR. PLYMOUTH TWP., MI. 48170 (734) 414-6500
*** PASSWORD PROTECTION OPTION ***
KEI-200A SET UP PROCEDURE
Press 0 -
From the Main Menu to enter Setup Mode. The unit should display as follows:
0=CLOCK 1= CONFIG
2=SET PASSWORD
Press 0
- To set the DATE and TIME (time is 24 hr mode):
Press sample key to continue.
Press 1
- To setup Configuration for:
•
CFG Operator ID:
The operator will be prompted for an ID number before collecting
data.
•
CFG Aligmnt M. # :
The operator will be prompted for a machine number before
collecting data.
•
CFG Barcode Scan:
The operator will be prompted to scan a barcode or manually
enter a VIN number before collecting data.
•
CFG Work Shift:
The operator will be prompted for an operator shift number before
collecting data.
•
CFG Slow Powerup:
This parameter enables or disables the slow powerup mode.
The slow powerup mode displays the Time & Date when powering up.
•
Vehicle/Tire Type:
The operator will be prompted for a vehicle type code before
collecting data.
Press 1 to set ON
Press 0 to set OFF
ST = Status of current setting.
Press 0 ,1,or Sample key to move to the next screen
Press 2-
To Set a Password for the configuration menu. This password is required to make
any changes to the configuration menu.
To turn the password protection
OFF
for the configuration menu, the user has to set the
password again and when the user is prompted to enter a new password press the sample
button. This will disable the password protection.
* Note :
Backlight will automatically turn off 1-2 min. after the last keystroke. To reactive press
any numeric key.