CALIBRATION PROCEDURE:

 

 

• 

Charge unit over night before calibrating. 

 

• 

Install mechanical steering wheel fixture (with inclinometer permanently mounted onto it) 
onto a calibration stand that can be adjusted for 0 degrees and some other known value 
such as 5 or 10 degrees. 

 

• 

Set the cal. stand to 0 degrees and adjust the ZERO control on the front panel of the 
inclinometer for 00.0 degrees. 

 

• 

Set the cal. stand to eg. 10 degrees and adjust the GAIN control on the front panel of the 
inclinometer for 10.0 degrees. 

 
Repeat the following two procedures until the values are stable.

 

 
WARRANTY AND SERVICE INSTRUCTIONS 

 
KEMKRAFT Engineering, Inc. warranties this equipment against defects in workmanship and 
materials for a period of 90 days from date of signature of release. We will, at our option, 
repair or replace products which prove defective during the warranty period. No other 
warranty, expressed or implied, is given. KEI is not liable for consequential damages. Damage 
caused to the equipment as a result of improper use or abuse, or unauthorized modification of 
the instrument is not covered under this warranty. 
 
For service contact:  

KEMKRAFT Engineering, Inc. 

    47650 

Clipper 

Dr. 

 

 

 

 

Plymouth Twp., MI.  48170   

 

 

   

PH: (734) 414-6500 

 

 

   

FAX: (734) 414-6599 

 

Содержание KEI-200A

Страница 1: ...INC MODEL KEI 200A SPC DIGITAL INCLINOMETER 96 014 doc Page 1 of 8 47650 CLIPPER DR PLYMOUTH TWP MI 48170 734 414 6500 INSTRUCTIONAL MANUAL SPC DIGITAL INCLINOMETER MODEL KEI 200A W BAR CODE OPTION REVISION DATE JAN 26 1999 ...

Страница 2: ... switch located on the front panel The unit will first display a 2 second Intro Message of DATE TIME Firmware version The unit should display the MAIN MENU as follows KEI200 A 0 SETUP 1 RUN 2 DOWNLOAD Setup should be performed and set to the users parameters before use KEI 200A SET UP PROCEDURE Press 0 From the Main Menu to enter Setup Mode The unit should display as follows SETUP 0 CLOCK 1 CONFIG...

Страница 3: ... 1 2 min after the last keystroke To reactive press any numeric key KEI 200A AUDIT PROCEDURE Press 1 To enter Run mode The unit should display as follows XX Xdeg XXXsmpl avg XXXavct XX Xdeg displays the degree angle value up to a max of 17 5 deg smpl is the sample counter and indicates the amount of samples stored into the units memory Maximum samples 249 avg is the abbreviation for average and wi...

Страница 4: ...e unit can than be turned off and taken to a computer that has a serial port Checksum Error This message indicates that the memory checksum is invalid The system will initialize the memory to default values after the operator has acknowledged the message RS 232 C SERIAL UPLOAD PROCEDURE Press 2 To enter the Download menu The unit should display as follows DOWNLOAD 1 BEGIN 0 CLEAR MEMORY Press 0 To...

Страница 5: ... control on the front panel of the inclinometer for 10 0 degrees Repeat the following two procedures until the values are stable WARRANTY AND SERVICE INSTRUCTIONS KEMKRAFT Engineering Inc warranties this equipment against defects in workmanship and materials for a period of 90 days from date of signature of release We will at our option repair or replace products which prove defective during the w...

Страница 6: ...KEI200 A 0 SETUP 1 RUN 2 DOWNLOAD Press 1 To enter Run mode The unit should display as follows Scan the Barcode SMPL when done Press SMPL To enter the VIN number in manually Barcode Scanner Gun Option Direct the scanner at the desired build sheet VIN and press the trigger The scanner will emit a visible RED horizontal beam This beam scans the bar code When the scanner has a good scan a green LED o...

Страница 7: ...gh KEMKRAFT ENGINEERING QuickScan 6000 Hand Held Laser Scanner 1 Programming Guide Booklet RS 232 Interface Section 2 Set Baud Rate 9600 3 Set 8 Bit Data 4 Set 1 Stop Bit 5 Set Parity NONE 6 Disable CTS RTS 7 Disable Xon Xoff 8 Set 20 ms Intercharacter Delay 9 Set Very Low power Mode Scanteam 2400 Hand Held Wand Scanner 1 User s Guide 2 Initialize word length 8 Data Bits 1parity 1 Stop 3 Set Parit...

Страница 8: ...ng data CFG Work Shift The operator will be prompted for an operator shift number before collecting data CFG Slow Powerup This parameter enables or disables the slow powerup mode The slow powerup mode displays the Time Date when powering up Vehicle Tire Type The operator will be prompted for a vehicle type code before collecting data Press 1 to set ON Press 0 to set OFF ST Status of current settin...

Отзывы: