KEMKRAFT KEI-200A Скачать руководство пользователя страница 6

KEMKRAFT

 

ENGINEERING, INC.

 

MODEL KEI-200A SPC DIGITAL INCLINOMETER

 

 

96-014.doc 

 

Page 6 of 8 

47650 CLIPPER DR.  PLYMOUTH TWP.,  MI.  48170  (734) 414-6500 

Barcode SCANNER Option 

 

 

The KEI-200A was developed to allow the user to scan a Vehicle Identification Number (VIN) 

of the vehicle that is being audited.  This allows the VIN to be stored along with the drive audit 

average for the vehicle.  This information can be uploaded to a P.C. for S.P.C. 

 

OPERATION

 

 

The KEI-200A is designed to have the scanner plugged directly into the 9 pin serial port.  

 

1). This port provides power and communication to barcode scanner. 

 

2). This port is also used to upload the stored audit data. 

 

Plug the bar-code scanner into the serial port. 

 

Toggle the power switch, located on KEI-200A the front panel, to turn the unit on.  The 

barcode scanner will beep to confirm power up.  The unit should display the following: 

 

KEI200-A  0=SETUP

 

1=RUN  2=DOWNLOAD

 

 

Press 1

 - To enter Run mode.  The unit should display as follows: 

 

Scan the Barcode

 

[SMPL] when done

 

 

Press SMPL

 

-

  To enter the VIN number in manually.   

 

Barcode Scanner Gun Option:

 

 

Direct the scanner at the desired build sheet VIN and press the trigger.  The scanner will emit 

a visible RED horizontal beam.  This beam scans the bar-code.  When the scanner has a 

good scan, a green LED on the unit will blink and the unit will beep.  The KEI-200A should 

display the following: 

 

Barcode Scanner Wand Option:

 

 

Place the scanner tip to the left of the desired build sheet VIN and press the trigger.  Draw a 

line with the tip of the scanner across the VIN barcode.  When the scanner has a good scan, a 

green LED on the unit will blink and the unit will beep.   

 

The KEI-200A should display the following: 

 

 

VIN 

XXXXXXXXXX 

Save?  1=Yes   0=N0

 

 

Press 0:

 To discard the scanned VIN number.  The saved Drive Audit Data will not have a VIN 

number. 

Press 1:

 To apply the scanned VIN number to the Drive Audit data. 

 
The KEI-200A is now ready for a Drive Audit. (Refer to Operating Procedure.) 

 

Содержание KEI-200A

Страница 1: ...INC MODEL KEI 200A SPC DIGITAL INCLINOMETER 96 014 doc Page 1 of 8 47650 CLIPPER DR PLYMOUTH TWP MI 48170 734 414 6500 INSTRUCTIONAL MANUAL SPC DIGITAL INCLINOMETER MODEL KEI 200A W BAR CODE OPTION REVISION DATE JAN 26 1999 ...

Страница 2: ... switch located on the front panel The unit will first display a 2 second Intro Message of DATE TIME Firmware version The unit should display the MAIN MENU as follows KEI200 A 0 SETUP 1 RUN 2 DOWNLOAD Setup should be performed and set to the users parameters before use KEI 200A SET UP PROCEDURE Press 0 From the Main Menu to enter Setup Mode The unit should display as follows SETUP 0 CLOCK 1 CONFIG...

Страница 3: ... 1 2 min after the last keystroke To reactive press any numeric key KEI 200A AUDIT PROCEDURE Press 1 To enter Run mode The unit should display as follows XX Xdeg XXXsmpl avg XXXavct XX Xdeg displays the degree angle value up to a max of 17 5 deg smpl is the sample counter and indicates the amount of samples stored into the units memory Maximum samples 249 avg is the abbreviation for average and wi...

Страница 4: ...e unit can than be turned off and taken to a computer that has a serial port Checksum Error This message indicates that the memory checksum is invalid The system will initialize the memory to default values after the operator has acknowledged the message RS 232 C SERIAL UPLOAD PROCEDURE Press 2 To enter the Download menu The unit should display as follows DOWNLOAD 1 BEGIN 0 CLEAR MEMORY Press 0 To...

Страница 5: ... control on the front panel of the inclinometer for 10 0 degrees Repeat the following two procedures until the values are stable WARRANTY AND SERVICE INSTRUCTIONS KEMKRAFT Engineering Inc warranties this equipment against defects in workmanship and materials for a period of 90 days from date of signature of release We will at our option repair or replace products which prove defective during the w...

Страница 6: ...KEI200 A 0 SETUP 1 RUN 2 DOWNLOAD Press 1 To enter Run mode The unit should display as follows Scan the Barcode SMPL when done Press SMPL To enter the VIN number in manually Barcode Scanner Gun Option Direct the scanner at the desired build sheet VIN and press the trigger The scanner will emit a visible RED horizontal beam This beam scans the bar code When the scanner has a good scan a green LED o...

Страница 7: ...gh KEMKRAFT ENGINEERING QuickScan 6000 Hand Held Laser Scanner 1 Programming Guide Booklet RS 232 Interface Section 2 Set Baud Rate 9600 3 Set 8 Bit Data 4 Set 1 Stop Bit 5 Set Parity NONE 6 Disable CTS RTS 7 Disable Xon Xoff 8 Set 20 ms Intercharacter Delay 9 Set Very Low power Mode Scanteam 2400 Hand Held Wand Scanner 1 User s Guide 2 Initialize word length 8 Data Bits 1parity 1 Stop 3 Set Parit...

Страница 8: ...ng data CFG Work Shift The operator will be prompted for an operator shift number before collecting data CFG Slow Powerup This parameter enables or disables the slow powerup mode The slow powerup mode displays the Time Date when powering up Vehicle Tire Type The operator will be prompted for a vehicle type code before collecting data Press 1 to set ON Press 0 to set OFF ST Status of current settin...